Easy calibration & test data storage, Sample integrity is never in question, Measured parameters – Teledyne Portable Pollution Emissions Monitor 9950 User Manual

Page 3: Calculations

Advertising
background image

Easy Calibration & Test Data Storage

An auto-zero feature for the gas sensors takes

even more of the work out of your hands. Span settings

are carried out by means of front-panel control switches,

and keypad controls remain functional during setup,

allowing the operator to select any analysis parameters

or fuels as necessary. All settings remain in memory –

even when power is turned off – and will be stored until

amended by the user or the analyzer is deliberately "cold

started" to clear the memory.

The 9950 stores up to 99 individual tests (including

a complete set of measurements and boiler ID number)

which are maintained in a non-volatile memory and can

be retrieved for printout for downloading via the RS-232

serial port.

Sample Integrity is Never in Question

Model 9950 accomplishes sample conditioning

through a fully integrated handling system capable of

delivering stack gas to the analyzer without

compromising integrity. A stainless steel probe is

connected to the monitor by a flexible hose. A high-

efficiency vane pump draws the sample through the

probe and into a coalescing filter where particulates and

condensates are removed prior to analysis, assuring you

the highest accuracy possible. Water and particulate

matter are automatically pumped from the system.

Measured Parameters

Range*

Resolution Accuracy

Oxygen (0

2

)

0-25%

0.1%

+/-1%FS**

Electrochemical cell
Expected Life - 24-36 months

Carbon Monoxide

0-2000 ppm

1ppm*

+/-3%FS**

Electrochemical cell
Expected Life - 24-36 months

Sulfur Dioxide (SO

2

)

0-1000 ppm

1ppm*

+/-3%FS**

Electrochemical cell
Expected Life - 24-36 months

Nitric Oxide (NO)

0-2000 ppm

1ppm*

+/-3%FS**

Electrochemical cell
Expected Life - 24-36 months

Nitrogen Dioxide (NO

2

)

0-200 ppm

1ppm*

+/-3%FS**

Electrochemical cell
Expected Life - 24-36 months

Combustion Gas Temperature 0-850°C

1°C

K-type thermocouple

continuous
0-1200°C

1°C

intermittent

Ambient Temperature

0-50°C

1°C

(for less than 85% relative humidity)

0-40°C

(for 85% relative humidity-printer specifications)

Calculations

Range

Resolution

Accuracy

Carbon Dioxide (CO

2

)

0-20%

0.1%

+/-5%

Combustion Efficiency

0-100%

0.1% varies with application

Pollutant Emissions

0-9.999

0.001

+/-3%

lbs / million BTU

* Please contact factory regarding non-standard ranges.
** At constant temperature once thermal equilibrium is achieved.

Options

Probe and hose lengths
NOTE: longer lengths may not fit within case
Selected optimal ranges for the
CO / SO

2

/ NO / NO

2

analysis are available

Remote display unit

TELEDYNE ANAL

YTICAL

INSTRUMENTS

MODEL

9950 PEM

2:18 PM 1/19/98

FUEL

NO.: #2 OIL

COMBU. EFF

.: 70.1%

STACK

TEMP

.: 820˚F

O

2

:

4.8%

CO: 987 PPM

CO

2

: 1

1.5%

NO:

2 PPM

NO

2

: 1

PPM

NOX (NO+NO

2

): 3 PPM

SO

2

: 1 PPM

SO

2

O

2

NO CO

NO

2