( 3 ) Using the unit with external sync signal

When adjusting H (horizontal) phase refer to the item "7.2 (5) (5.1) Adjusting horizontal phase".

(3. 1) H (horizontal) phase adjustment

Observe the external sync signal and the video signal output
waveform of the unit with a dual trace oscilloscope, and ad-
just H phase so that the H phases match.

( 4 ) Changing HD/VD input/output

(1) Put off 6 screws both on flank/top of camera chassis.

(2) Change internal switch SJ01(HD/VD).

External
Sync. signal

Match
the phase.

Camera
Video output

HD/VD OUTPUT

HD/VD INPUT high-impedance

HD/VD INPUT 75

(factory setting)

SJ01

7. 4 Synchro. Scan Operatin

The shutter speed can be set by the horizontal scanning period (1H) or by the frame.

( 1 ) Setting by 1H

1H/796H to 795H/796H (1H/387H to 386H/387H when partial scanning at 60fps, 1H/258H to 257H/258H when
partial scanning at 90fps) stands for the setting by the 1H and the shutter speed can be set by the 1H (43.05

µ

s).

( 2 ) Setting by the frame

2FRM to 512FRM stand for the setting (long period exposure) by the frame.

The video signal stored during the frame period set is output as 1 frame video image at a frame interval
specified.