Electrical installation, Cit304 models, Cit365 models – Thermador CIT365 User Manual

Page 10

Advertising
background image

11

Electrical installation

You can find the identification plate with the electrical specifications on the
underside of the appliance. The junction box must be located within 3 feet
(

~

900 mm) of the cooktop connection. It should be easily accessible for service

purposes.

3 1/4” max (79 mm) + Fitting/Conduit 1” (23 mm)

Connection
(”J”) box

Conduit approx. 3 ft. (

~

900 mm)

12” approx. (300 mm)

1” min (26 mm) air clearance

Power supply

CIT304 Models...

40 Amp circuit breaker

240 Volts, 3 Wire, 60 Hz
208 Volts, 3 Wire, 60 Hz

All with 39" (1m) flexible conduit (included)

CIT365 models...

50 Amp circuit breaker

240 Volts, 3 Wire, 60 Hz
208 Volts, 3 Wire, 60 Hz

All with 39" (1m) flexible conduit included

Electrical requirements