Telex PS-4001 User Manual

Page 4

Advertising
background image

4

1.

Universal AC Power Input: The unit accepts any input power in the range opf 100-240 VAC, 50/60 Hz.

2.

Connector to ES-4000A: This connector carries power to the ES-4000A expansion station, and carries the four audio
channels of the ES-4000A. When a Telex ES-4000A is connected to the PS-4001, each of the four channels of audio
is “broken out” to the respective channel connections.

3.

Intercom Channel Connectors: These connectors carry power to the intercom system and provide termination for the
audio signal of each individual intercom channel.

4.

Channel Status Indicators: The indicators are green for normal operation and red when there is an overload or short
circuit. The circuitry in the unit will automatically reset when the overload or shirt circuit is located and fixed, and the
LED will go back to green.

5.

BAL/UNBAL Selector Switch: This selector switch allows the user to configure the unit for use in either an

Audiocoom (BALANCED) or ClearCom

(UNBALANCED) system. Compatibility includes channel connector pin-

outs, channel power requirements, and call signaling requirements. The default setting for this switch is in the
Audiocom (BAL) position.

NOTE:

In order to connect the PS-4001 to a 2-channel ClearCom system using a 6-pin connector, an adaptor cable,

shown in Figure 2, must be constructed.

FIGURE 2.

ClearCom Cable Assembly

Advertising