Texas Instruments DEM-DAI3010 User Manual

Page 9

Advertising
background image

Use of the DEM-DAI3010

1-3

Description

1.2

Use of the DEM-DAI3010

The DEM-DAI3010 is shipped with standard settings preset. Therefore,
connecting power supplies (15-V, –15-V and 5-V) is the only requirement to
prepare the board for use, unless nonstandard settings are desired.

1.2.1

Initial Settings of the DEM-DAI3010 (at shipping)

Table 1–1. Initial Settings of the DEM-DAI3010 at Shipping

Item

Initial Setting (at shipping)

Power supply voltage

15 V, –15 V, and 5 V (close CN57)

Power supply terminals

CN51–CN55 (open CN56)

Connection of PCM3010 and S/PDIF I/O

DIR1703 and DIT4096 connected with JP107

DIR1703 system clock (SCK)

256 f

S

DIR1703 output audio data format

I

2

S

DIR1703 crystal clock frequency

24.576 MHz (load capacitance: 18 pF)

DIT4096 system clock (SCLK)

256 f

S

DIT4096 input audio data format

I

2

S

PCM3010 system clock

Automatic selection (no setting required)

PCM3010 I/O audio data format

I

2

S

PCM3010 power-down function

Disabled

PCM3010 de-emphasis function (DAC)

Disabled

PCM3010 DAC cutoff frequency

54 kHz (JP101–JP104 are closed)

PCM3010 ADC input terminal selection

CN101, CN102: 2-V rms input (with LPF)

1.2.2

How to Connect Power Supplies to the DEM-DAI3010

The DEM-DAI3010 requires 5-V, 15-V, and –15-V power supplies. Power is
supplied to this board by five binding posts (one each for V

CC

= +5 V, +AV

CC

= +15 V, –AV

CC

= –15 V, and two for ground) from stabilized dc power supplies.

V

DD

(3.3 V) for the PCM3010 is normally generated by an onboard

voltage-regulator IC from V

CC

(5 V), but it is possible to supply 3.3 V directly.

To do so, open CN057, then supply 3.3 V to CN056 and 5 V to CN054. If 3.3
V is supplied externally, 5 V must still be provided to CN054 in order to supply
the analog section of the PCM3010. To avoid latch-up of the PCM3010, ensure
that V

CC

and V

DD

are powered up simultaneously.

Table 1–2. Power Supply Terminals and Supply Voltage (Depending on CN057 Setting)

Power Terminal

CN057 Closed (Default)

CN057 Open

CN051 (orange)

15 V

15 V

CN052 (green)

0 V (ground)

0 V (ground)

CN053 (blue)

–15 V

–15 V

CN054 (red)

5 V

5 V

CN055 (black)

0 V (ground)

0 V (ground)

CN056 (2-pin connector)

Open (no connection)

3.3 V

Advertising