NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

18

Chimney Section

63L10

FTF8-12

63L13

FTF8-18

63L14

FTF8-36

63L15

FTF8-48

Canadian

62L92

FTF8-18C

Chimney Section

62L93

FTF8-36C

Take Off Boot

91L04

FATO

Outside Combustion Air Kits
(with duct)

81L87

FOAK

(without duct)

81L88

FOAK-LD

Secure the hearth extension to the floor to
prevent possible shifting.

FINISH TO YOUR TASTE

There are a wide variety of “finished looks” for
these fireplaces, from formal wall decor with
elaborate mantels to rustic wood paneling or
warm brick facings.

Only noncombustible materials like stone, tile,
brick, etc., may overlap the black front facing.
Do not extend these materials beyond the black
facing and into the firebox area. Be sure not to
interfere with the installation and operation of
glass doors or block the upper or lower grilles.
Seal all joints between the black facing and wall
surrounds to prevent air intrusion. Use non-
combustible caulking material only to seal the
black metal facing to the surround material on
the finished wall.

Combustible materials may project beyond the
sides of the fireplace opening as long as they
are kept within the shaded areas illustrated in
Figure 52.

Figure 51

Figure 52

12"

12"

Min. Distance To

Unprotected Side Wall

8"

45

°

Combustible

Materials

Allowed In

Shaded Area

“Safe Zone”

8"

1"

Min. Distance To

Protected Side Wall

Fireplace

A

³⁄₄" marble slab set in ¹⁄₂" mortar covers the

brick, “R” for the marble and mortar becomes:

“R”

M

= r x T

M

= 0.09 x

³⁄₄" = .068

“R”

M

= r x T

M

= 0.20 x

¹⁄₂" = .10

The sum of all “R values” is:

.70 + .10 +. 068 + .10 = .968

This would be an acceptable combination of
material for the hearth extension since the
total calculated “R value” of the materials used
exceeds the required “R value” of 0.78.

WARNING: THE CRACK BETWEEN THE
FIREPLACE AND THE HEARTH EXTEN-
SION MUST BE SEALED WITH A NON-
COMBUSTIBLE MATERIAL.

WARNING: WHEN INSTALLING HEARTH
EXTENSION IN FRONT OF A NON-CIRCU-
LATING FIREPLACE MODEL, THE FIRE-
PLACE MUST BE RAISED IF HEIGHT OF
HEARTH EXTENSION EXCEEDS 7" ABOVE
THE BOTTOM OF FIREPLACE (

FIGURE 50 ).

WARNING: WHEN INSTALLING THE
HEARTH EXTENSION BE CAREFUL NOT
TO BLOCK THE HEAT-CIRCULATING AIR
INLET GRILL ON CIRCULATING MODELS.

WARNING: WHEN INSTALLING HEARTH
EXTENSION IN FRONT OF A CIRCULAT-
ING FIREPLACE MODEL, THE FIREPLACE
MUST BE RAISED IF HEIGHT OF HEARTH
EXTENSION EXCEEDS 2" ABOVE BOTTOM
OF FIREPLACE (

FIGURE 51 ).

Figure 50

5 1/2"

2"

Max. Thickness Of Hearth Extension When

Circulating Models Are On The Floor

Shipping Weight

175 lbs.

INSTALLATION COMPONENTS

The following items are available for use in the
installation of this appliance.

Combination
Offset/Return Elbow

63L28

FTF8-OR15

7"

Max. Thickness Of Hearth Extension When

Non-Circulating Models Are On The Floor