Parametric Equalisation

Eight sections of equalisation are provided, two shelving filters and six fully variable
parametric sections.

High and Low shelving filters

LMS-D26

In A Freq Slope Gain

EQ1 100Hz 12dB 0.0dB

a

b

c

a

b

c

Knob A: Frequency, 10.0Hz to 25.6kHz in variable steps

Knob B: Slope, 6 to 12dB / octave in 1dB steps
Knob C: Gain, +/-15dB in 0.2dB steps
The frequency is specified as point where the filter deviates by 3dB from the gain value.

Parametric filters

LMS-D26

In A Freq Width Gain

EQ1 100Hz 1.4Q 0.0dB

a

b

c

c

b

a

Knob A, Centre Frequency, 10.0Hz to 25.6kHz in variable steps
Knob B, Width, display selectable, Q or BW (Bandwidth)
BW adjustable from 0.05 to 5 octaves in variable steps
Q adjustable from 14.2 to 0.2 in variable steps
Knob C, Gain, +/-15dB in 0.2dB steps