TOA Electronics SLDVT-40 User Manual

Page 4

Advertising
background image

4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Millivolt appliances - Appliances with

Millivolt systems will be fitted with the gas

control valve shown in Figure 3.

electronic appliances - Appliances with

electronic systems will be fitted with the

electronic valve shown in Figure 4.

Millivolt appliances - To light millivolt ap-

pliances refer to

Figure 2. Detailed lighting

instructions are found on Pages 18 & 19 . Mil-

livolt appliance lighting instructions may also

be found on the pull out lighting instruction

labels attached to the gas control valve.

Once the pilot is lit, the main burner may be

turned ON and OFF using wall switch, remote

control, optional on unit rocker switch (FRS),

or wall thermostat. To operate: Toggle the

switch between its ON and OFF positions.

If your millivolt appliance is equipped with an

optional remote switch kit (wall switch, remote

control, rocker switch, or wall thermostat) and

the pilot is lit, the appliance main burner may be

turned on and off using the optional switch.

Note: To prevent excessive resistance in burner

circuit (which can cause burner operation prob-

lems), only one burner control switch should

be wired to valve.

electronic appliances -

To light electronic appliances refer to the detailed

lighting instructions found on

Pages 20 & 21

of these instructions. Electronic appliance

lighting instructions may also be found on the

pull out lighting instruction labels attached to

the gas control valve.

If your electronic appliance is equipped with an

optional remote wall switch or remote control kit

the appliance main burner may be turned on and

off with the wall switch or remote control.

If your electronic appliance is not equipped with

a wall switch or remote control, the main burner

must be turned off and on with a gas control

switch located in some other location by the

installer. Contact the installer for directions.

Variable Flame Height adjustment

1. All millivolt appliances are equipped with a

variable gas control valve. Flame height for

these models may be adjusted through a

range between fixed low and high settings

while the appliance is in operation. Adjust

the flame height as desired after lighting the

appliance by rotating the variable adjustment

control knob (HI/LO) located on the front of

the valve (refer to Figures 3 & 4 ).

Figure 4

SIT Millivolt Gas Valve

Figure 3

Dexen Electronic Gas Valve

Pilot Stage

Terminal

Pressure-Tap

(Inlet)

Pilot Gas

Outlet

Supply Gas

Inlet

Pressure-Tap

(Manifold)

Burner Stage

Terminal

Ground

(TP)

PILOT

OUT

VENT

LO

TH

TP

TH

TP

HI

IN

IN

Gas Outlet

To Burner

Regulator

Mounting Screw

Variable Flame

Height Adjustment

Manifold Pressure

Port

Inlet

Pressure

Port

Main Gas Control Knob

H I

LO

W

TPTH

TP

TH

PIL

OT

PI

LO

T

ON

it

OFF

IN

OUT

Gas Inlet

Terminals TPTH, TP & TH

Gas

Outlet

Figure 2

Gas Flex Line

5 Inch

Pipe Nipple

Valve

Piezo

Spring Door Latch

Advertising
This manual is related to the following products: