Automatic track division, Rec mute function, Automatic track division rec mute function – Tascam CC-222MKII User Manual

Page 31: 5 – recording cds—advanced recording

Advertising
background image

5 – Recording CDs—Advanced recording

TASCAM CC-222MKII

Owner’s Manual

31

Automatic track division

The trigger level, as set above (“Synchronized
recording” on page 29
) can also be used to divide
tracks if the A-TRACK (auto track) function is
enabled.

When this function is enabled, the unit automatically
inserts a track division in the recorded material when:

• recording digitally from MD, CD or DAT, an incre-

ment signal is detected and the sound level rises
above the threshold:

or

• increment signals are unavailable (e.g. analog

recording or digital sources other than MD. CD or
DAT) and the sound level has dropped below the
threshold for more than two seconds, and sound
has re-started:

To enable or disable automatic track division:

1

With a recordable disc inserted, press the

MENU

key repeatedly until

A_TRACK>XX

is shown, where

XX

may be

ON

or

OFF

.

2

Turn the

MULTI DIAL

or use the

SKIP

keys to

change the value as required.

The

A-TRACK

indicator at the top right of the

display lights when the auto track function is
enabled.

3

Press the

RECORD

key.

NOTE

When recording certain types of material (e.g. certain
types of classical music or spoken word) through the
analog connections, since the track divisions are deter-
mined by relative silence, it is possible that spurious
track divisions will be inserted. Under these conditions,
it may be better to use manual track division (“Manual
track division” on page 27)
.

It is not possible to turn this function on and off when
recording.

However, if recording through a digital connection, the
track number will be incremented only when a track
division signal is received, followed by a rise in volume.

A fall and subsequent rise in volume alone when
recording digitally from CD, MD or DAT is not sufficient
to trigger an automatic track increment.

Rec mute function

The rec mute function allows instant cut-off of the
input signal, and records four seconds of silence on
the disc.

1

While recording is in progress, press the

REC

MUTE

key.

The display shows

REC MUTE

, the meters

stop displaying the current level and the
monitored sound is cut.

2

After about four seconds, the unit enters
record ready mode.

time

level

S_LVL

CD-RW
increments
track

Track increment
from source

time

level

S_LVL

At least 2

seconds

Track
increment

time

level

S_LVL

Track incremented

Track start signal
received

time

level

S_LVL

Long "pause"
in signal, but
track is not
incremented

Digital recording from CD, MD and DAT

Advertising