Team Products PMP200XL User Manual

Page 7

Advertising
background image

PMP200XL Models

Owner’s Manual

Reason

Solution

Poor contact with

Unplug and reinsert 12

lighter socket or

volt plug or reattach

battery terminals.

battery clips.

Using incorrect type of

Use true RMS reading meter.

voltmeter to test
output voltage.

Reason

Solution

Battery voltage below

Recharge or replace battery.

10.0 ± 0.5 volts.

Equipment being operated

Use a higher capacity inverter

draws too much power.

or do not use this equipment.

Inverter is too hot (thermal

Allow inverter to cool.

shutdown mode).

Check for adequate ventilation.

Reduce the load on the

inverter to rated continuous

power output

Unit may be defective.

See Warranty and call

Customer service at

1-888-231-4022.

Troubleshooting

PROBLEM: Low or No Output Voltage

PROBLEM: Red LED On

9

Reason

Solution

Electrical interference from

Add an AC interference filter on

the inverter.

to the TV power cord. Refer

to TV and audio section of

this manual.

Reason

Solution

TV does not turn on.

Try turning the inverter

ON/OFF/ON.

Contact TV manufacturer for

start up surge and power

consumption.

A larger inverter may

be required.

PROBLEM: TV Does Not Work

Reason

Solution

Input voltage below10.5 ± 0.5 volts.

Keep input voltage above 10.5±0.5

volts to maintain regulation.

Poor or weak

Recharge or

battery condition.

replace battery.

Inadequate power being

Check condition of cigarette

delivered to the inverter

lighter socket. Clean or

or excessive voltage drop.

replace if necessary

Troubleshooting

PROBLEM: TV Interference

PROBLEM: Low Battery Alarm On All The Time

10

PMP200XL_122205M.indd 14-15

12/22/05 9:09:50 AM

Advertising