Specifications wiring – Tamarack Technologies GH.02 User Manual

Page 3

Advertising
background image

Electrical:

Voltage

Power

Air Flow

Operation

Insulation Value of

Closed Doors

Weights

Top Housing

Lower Housing

115 VAC 60Hz

(High Speed) 450 Watts
(Low Speed) 340 Watts

High Speed 3400 CFM
Low Speed 1900 CFM

30 second Door Cycle Time
(Open-Close)

MODEL GH: R-22
MODEL GHD: R-38

Whole House Ventilator: 48 Lbs.
Shipping: 67 Lbs.

26 1/4” long x 26” W x 14 1/8’ H

25 7/8” long” x 29 1/2” W
x 13 5/8” H

specificationS

wiring

WARNING:

State and local

electrical codes may require
that the GHOST be installed

by a licensed electrician.

Check with your local code

officials before installing.
Be sure to turn off power

before wiring the GHOST

Whole House fan.

Figure 6.

Figure 7.

6. Rotate the upper housing until it lines up with the
lower housing. Make sure the edges of the two hous-
ings mate all the way around the GHOST (Figure 6)
and then pull the black attachment handles down over
their attachment posts (Figure 7).

7. If desired, secure the GHOST to the top of the joists.

8. Plug the connector from the GHOST into the Control
Box. Plug the Control Box into an unswitched,
grounded receptacle.

9. Install the ceiling grille (screws provided).

10. Check the unit for proper operation:

Turn the unit on - it will take 30 seconds for the

doors to open.

Fan starts - the fan should start and run

smoothly.

Be sure at least one window is open when the

fan is operating.