INSTALLATION

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when setting the 4-position switch and the jumper(s) and when
installing the Slide-in-Module. Failure to observe this caution could result in
damage to, and subsequent failure of, the Media Converter.

Set the 4-Position Switch

The 4-position switch is located on the
side of the Media Converter. Use a
small flatblade screwdriver or a similar
device to set the recessed switches.
Refer to the drawing for the locations
of the four individual switches.

1. Auto-Negotiation
UP

Enables Auto-Negotiation on the copper port.
Advertises 100 Mb/s full-duplex and half duplex,
and 10 Mb/s full-duplex and half duplex.

DOWN

Disables Auto-Negotiation on the copper port.

2. Copper Mode
(Applies only if switch 1 is DOWN.)
UP

Forces full-duplex operation on the copper port.

DOWN

Forces half-duplex operation on the copper port.

3. Speed
(Applies only if switch 1 is DOWN.)
UP

Forces 100 Mb/s operation on the copper port.

DOWN

Forces 10 Mb/s operation on the copper port.

4. Fiber Mode
UP

Forces full-duplex operation on the fiber port.

DOWN

Forces half-duplex operation on the fiber port.

Speed (UP=100Mb/s)

Copper Mode (UP=Full-Duplex)

Auto-Negotiation (UP=Enabled)

Fiber Mode
(UP=Full-Duplex)

1 2 3 4

[email protected] -- Select the “Transition Now” Link for a Live Web Chat

3

INSTALLATION

-- Continued

Set the Jumpers

The jumpers are located on the Media Converter circuit board. Use small
needle-nosed pliers or a similar device to set the jumper.

The Hardware/Software jumper is labeled “H” for hardware and “S” for
software (see the drawing below).

Hardware The Media Converter mode is determined by

the 4-position switch settings listed above.

Software

The Media Converter mode is determined by
the most-recently saved, on-board
microprocessor settings.

The Far-End Fault jumper is labeled “FE” for enable Far-End Fault and “FD”
for disable Far-End Fault (see the drawing below).

Enable

A fault on the fiber link causes the Media
Converter to transmit a Far-End Fault signal.

Disable

No Far-End Fault signal is transmitted when a
fault occurs.

Software Mode

Hardware Mode

S

H

S

H

Disable Far-End Fault

Enable Far-End Fault

FE

FD

FE

FD

Installing the Slide-In-Module

CAUTION: Slots in the PointSystem™ Chassis without a Slide-in-Module
installed MUST have a protective plate covering the empty slot for Class A
and/or Class B compliance.

To install the CGETF10xx-15x Media Converter Slide-in-Module:
1.

Locate an empty installation slot on the PointSystem™ Chassis.

2.

Carefully slide the Slide-in-Module into the installation slot, aligning the
Slide-in-Module with the installation guides.

3.

Ensure that the Slide-in-Module is firmly seated against the back of the
chassis.

4.

Secure the Slide-in-Module by securing the panel fastener screw
(attached to the Slide-in-Module) to the chassis front.

CFMFF100

10BASE-2

CECF100

CFMFF100

0

50½

Link Alert

E

D

CETCF100

CFETF100

CFETF110

CFMFF100

LA

PWR

RXF

RXC

LNK

COL

SPD

PWR

FRX

CRX

FLNK

CLNK

SPD

PWR

FRX

CRX

FLNK

CLNK

10/100TX

RX

TX

10/100SX

100BASE-TX

RX

TX

100BASE-FX

Link Alert

E

D

0

50½

LA

PWR

RXF

RXC

LNK

COL

LKS

PWR

LKM

10BASE-2

10BASE-FL

10BASE-T

LKS

PWR

LKM

LKS

PWR

LKM

Multimode

Singlemode

TX

RX

TX

RX

Multimode

Singlemode

TX

RX

TX

RX

Multimode

Singlemode

TX

RX

TX

RX

I

0

TERM

INIT

RX

TX

LNK

PWR

CPSMM120

SERIAL

10BASE-T

R

E

S

E

T

I

0

Panel Fastener Screw