Jbw50w type – TDK J Series JBW User Manual

Page 8

Advertising
background image

(8/30)

004-02 / 20070523 / ea122_jbw.fm

• All specifications are subject to change without notice.

JBW50W Type

SPECIFICATIONS AND STANDARDS

∗1

Current rating(maximum output current) is determined for –10 to +50°C. Derating is required when used outside this temperature range.

∗2

Please note that the deterioration of parts is occasionally caused when operating for a long time(over 10 minutes) with the voltage below the range of the
input voltage.

• Optional input, output cable kits are available at a separate price.

Part No.

JBW05-10R

JBW12-4R3

JBW15-3R5

JBW24-2R1

Rated output voltage and current

∗1

5V • 10A

12V • 4.3A

15V • 3.5A

24V • 2.1A

Maximum output power

W

50

51.6

52.5

50.4

Input conditions
Input voltage Eac/Edc

∗2

V

85 to 265[Rating: 100 to 240]/120 to 375

Input frequency

Hz

47 to 66[Rating: 50 to 60](Single phase)

Input current

A

0.7typ./0.88max. [AC.100V]0.35typ./0.5max.[AC.240V]

Fuse rating

A

3.15[AC.250V, built-in]

Surge current

A

15typ.(30max.)[AC.100V]40typ.(60max.)[AC.240V] cold start

Leakage current

mA

0.35typ./0.75max.[AC.100V, 60Hz]0.5typ./0.75max.[AC.240V, 60Hz]

Power factor

0.99typ./0.93typ.[AC.100/240V]

Efficiency

%

77typ.[AC.100V]

80typ.[AC.100V]

80typ.[AC.100V]

81typ.[AC.100V]

%

79typ.[AC.240V]

81typ.[AC.240V]

81typ.[AC.240V]

83typ.[AC.240V]

Output characteristics
Output voltage Edc

V

5

12

15

24

Voltage variable range Edc

V

4.5 to 5.5

10.8 to 13.2

13.5 to 16.5

21.6 to 26.4

Maximum output current

A

10

4.3

3.5

2.1

Minimum output current

A

0

0

0

0

Overvoltage threshold Edc

V

5.75 to 6.9

13.8 to 16.8

17.2 to 21

27.6 to 33.6

Overcurrent threshold

A

10.5min.

5.4min.

4.4min.

2.7min.

Voltage
stability

Source effect

%

0.4max.[Within the input voltage range]

Load effect

%

0.8max.[0 to 100% load]

Temperature effect

%

1max.[Ambient temperature: –10 to +50°C]

Drift(Time effect)

%

0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]

Recovery

%

±4max.[50 to 100% sudden load change]

Ripple Ep-p

mV

80max.

120max.

120max.

120max.

Ripple noise Ep-p

mV

120max.

150max.

150max.

150max.

Start up time

ms

500max.(400typ.)/500max.(400typ.) [AC.100/240V]

Hold up time

ms

20typ./20typ. [AC.100/240V]

Auxiliary functions
Indicator display

No

Overvoltage protection

Voltage shut-down type.

Overcurrent protection

Rectangular type, automatic recovery.

Remote ON-OFF

No

Remote sensing

No

Parallel operation

Impossible

Series operation

Possible

Output voltage external variable function

No

Standards
Safety standards

UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.

Noise terminal voltage

FCC-B, VCCI-B, EN55011-B, EN55022-B meet.

Input harmonics current requirement

EN61000-3-2 meet.

Constructions
External dimensions

mm

26

Ч 55Ч 190[HЧ WЧ L]

Weight

g

220max.

Mounting method

Can be attached to 1 side.

Case material

No(PWB Material: CEM3)

Advertising