MOUNTINGS (Reference)

1.NB59S, NB-80E TYPES

The transducer can beak off if the A dimension depth is shallow.

TDK recommends a 2mm A-dimension depth and a screw tighten-

ing torque of 0.6N • m.

2.CONSTRUCTION OF NB59S

The drawing below shows an example method for transistor heat

dissipation. The attached aluminum cooling fins should fixed using

silicon rubber to a metallic water tank, etc. with sufficient head dis-

sipation capacity.

(It is recommended to use a plastic water tank. However, if a

metallic water tank is absolutely must be used, be sure to insulate

it from the power supply line.)

PRECAUTIONS

• These units are readily damaged by operation when empty

(without water). Therefore a means (float switch, etc.) should be

provided to assure operation does not occur when empty.

• Contact TDK prior to use of this unit for applications utilizing

liquids other than water.

• The unit should be used only after sufficient consideration of the

product specifications for that specific unit.

• When using units in parallel, make sure that voltage differences

do not occur between the individual transducers.

• Do not use the unit to atomize a liquid other than drinking water.

Doing so can deteriorate the transducer.

• Do not operate the transducer when the atomization unit tank is

not charged with drinking water.

• Drain water from the transducer and clean the equipment into

which the unit is incorporated if not used for a long period of

time.

• Clean the transducer periodically to prevent any degradation in

the atomizing capacity due to buildup in the transducer of such

substances as calcium, sodium, magnesium, and silicon,

commonly found in drinking water.

• TDK is not responsible for damage to the transducer resulting

from use of oscillator circuitry not supplied or not approved by

TDK.

• TDK is not responsible for worsening of unit performance

resulting from operation in environments other than those

recommended, storage in environments other than those

recommended, or use of the unit in configurations other than

those recommended by TDK for efficient mist generation.

• TDK is not responsible for the vaporization of pathogenic

bacteria or particles, not responsible if drinking water contains

substances that impede vaporization, and not responsible for

bacterial growth due to lack of a water purification function.

• Please select a plastic material of construction for the water tank

design. Metallic construction can result in electrolytic corrosion

between the chamber base and water tank.

Furthermore, if multiple units are used with the same tank, and if

each unit is equipped to be separately turned ON/OFF, the

power supply terminal for each unit should use a double-pole

switch.

Screw:M4

×15

Rubber packing

Tank base

ш24

ш18

A

Dimensions in mm

Plastic case
(Metal case)

P.C. board

Metal tank

Transducer unit

Silicon rubber

Aluminum radiation board