Data port Command Interface User Guide

2.

Connecting to the Data port Command Interface through the RS-232 port.

The RS-232 port is a 9-pin, female, sub-D connector located on the front of the Video Portal. The port is configured
as a DCE (Data Communications Equipment). The RS-232 port is default set to 115200 baud, 8 data bits, none
parity and 1 stop bit from factory. The RS-232 port is also referred to as the Data port.

2.1.

Hardware and Cabling

The pin outs for the RS-232 are defined in the following table (the DTE, Data Terminal Equipment, could be a PC
or other device capable of serial communication).

Pin no

Signal

Description

Direction

1

CD

Carrier detect

To DTE

2 RD

Receive

data

To

DTE

3

TD

Transmit data

From DTE

4

DTR

Data terminal ready

From DTE

5

Ground

6

DSR

Data set ready

To DTE

7

RTS

Ready to send

From DTE

8

CTS

Clear to send

To DTE

9 RI

Ring

indicator

To

DTE

NOTE! A straight through cable should be used between the TANDBERG Video Portal’s RS-232 port and the DTE.

The figure below illustrates the recommended cable-wiring scheme for connecting the Video Portal to a PC through
RS-232.

TANDBERG

V

IDEO

P

ORTAL

PC

DCE, 9 pin

DTE, 9 pin

1 CD

1 CD

2 RD

2 RD

3 TD

3 TD

4 DTR

4 DTR

5 GND

5 GND

6 DSR

6 DSR

7 RTS

7 RTS

8 CTS

8 CTS

9 RI

9 RI

DTR and RTS are ignored. DSR, CD, and CTS are always asserted, while RI is not used.