Thermador POD302 User Manual

Page 10

Advertising
background image

10

Double Oven 30”

It is good practice, when oven is in-
stalled at the end of a cabinet run, ad-
jacent to a perpendicular wall or
cabinet door, to allow at least 1/4”
space between the side of the oven
and the wall/door.

For oven support, install 2x4’s extend-
ing front to back flush with the bottom
and the side of the opening. The sup-
porting base must be well secured to
the floor/cabinet and level.

Note: The conduit box must be located
above the unit to facilitate connecting
and servicing.

The cabinet base must be flat and
capable of supporting a weight of at
least 330 lbs (150 kg).

Combo Oven with Microwave 30”

It is good practice, when oven is in-
stalled at the end of a cabinet run, ad-
jacent to a perpendicular wall or
cabinet door, to allow at least 1/4”
space between the side of the oven
and the wall/door.

For oven support, install 2x4’s extend-
ing front to back flush with the bottom
and the side of the opening. The sup-
porting base must be well secured to
the floor/cabinet and level.

Note: The conduit box must be located
above the unit to facilitate connecting
and servicing.

The cabinet base must be flat and
capable of supporting a weight of at
least 290 lbs (132 kg).

Advertising
This manual is related to the following products: