Regulatory agency, Mechanical, Reliability – Tatung TLM-1506 User Manual

Page 16

Advertising
background image

16

6. Regulatory Agency

6.1 Safety Approvals

This series design shall meet the standards of the following domestic and foreign

agencies:

UL listed: UL60950-2000 listing (Information Processing and Business Equipment)

CUL Certified: CAN/CSA C22.2 No. 950-95 (Information Technology Equipment)

CE LVD: IEC 60950: 1999 3

rd

edition

CB: IEC 60950: 1999 3

rd

edition

6.2 EMI/EMS Emission Approvals

This series design shall meet following EMI/EMS specifications:

FCC Compliance: FCC Rules and Regulations, Part 15, subpart B, Class B.

CE COMPLIANCE: EN55022:1998 class B, EN55024:1998, EN50130-4:1998

EN 61000-3-2:2000, EN 61000-3-3:1995.


7. Mechanical

7.1 Weight
Model TLM1-1506

TLM-1706

TLM-1906

Net weight

4.1 KG/ 9.0 lb

5.0 KG/ 11.0 lb

6.4 KG/ 14.5 lb

Gross weight

5.8 KG/ 13.0 lb

6.8 KG/ 15.0 lb

8.6 KG/ 19.0 lb

7.2 Dimensions:
Model TLM-1506

TLM-1706

TLM-1906

Physical dimension

356(W) x 387(H) x 200(D)mm
14.0(W) x 15.2(H) x 7.9(D)inch

387(W) x 402(H) x 200(D)mm
15.2(W) x 15.8(H) x 7.9(D)inch

458(W) x 416(H) x 215(D)mm
18.0(W) x 16.4(H) x 8.5(D)inch

Packing dimension

432(W) x 470(H) x 203(D)mm
17.0(W) x 18.5(H) x 8.0(D)inch

450(W) x 470(H) x 203(D)mm
17.7(W) x 18.5(H) x 8.0(D)inch

546(W) x 521 (H)x 220(D)mm
21.5(W) x 20.5(H) x 8.7(D)inch

7.3 Wall mount:

Optional wall mount (VESA standard 100mmX100mm)


8. Reliability

Mean Time Between Failures (MTBF):

MTBF shall be 50,000 hours minimum at 90% confidence level and 100% duty cycle

continuous operation at 25

o

C. The calculation shall not include LCD panel.