Toshiba VF-FS1 User Manual
Page 148
E6581381
F-52
6
Title
Function
Adjustment range
Default setting
H
Acceleration time 2
0.0-3200 [s]
Depends on the
capacity
(
⇒ See page K-14)
H
Deceleration time 2
0.0-3200 [s]
Depends on the
capacity
(
⇒ See page K-14)
H
Selecting an acceleration/deceleration
pattern
: Acc / dec 1
: Acc / dec 2
1
1)
Selection using parameters
Time [s]
Output frequency [Hz]
FGE
CEE
HJ
H
H
0
H=
H=
Acceleration/deceleration time 1 is initially set as the default. Acceleration/deceleration time 2 can be
selected by changing the setting of the H.
Enabled if EOQF= (panel input enabled)
2)
Switching by frequencies - Switching the acceleration/deceleration time automatically at the frequency
setting of H.
Title
Function
Adjustment range
Default setting
H
Acceleration/deceleration 1 and 2
switching frequency
0.0-WN
0.0