Toshiba VF-FS1 User Manual

Page 148

Advertising
background image

E6581381

F-52

6

Title

Function

Adjustment range

Default setting

H

Acceleration time 2

0.0-3200 [s]

Depends on the

capacity

(

⇒ See page K-14)

H

Deceleration time 2

0.0-3200 [s]

Depends on the

capacity

(

⇒ See page K-14)

H

Selecting an acceleration/deceleration
pattern



: Acc / dec 1



: Acc / dec 2

1

1)

Selection using parameters

Time [s]

Output frequency [Hz]

FGE

CEE

HJ

H

H

0

H=

H=

Acceleration/deceleration time 1 is initially set as the default. Acceleration/deceleration time 2 can be
selected by changing the setting of the H.
Enabled if EOQF= (panel input enabled)

2)

Switching by frequencies - Switching the acceleration/deceleration time automatically at the frequency
setting of H.

Title

Function

Adjustment range

Default setting

H

Acceleration/deceleration 1 and 2
switching frequency

0.0-WN

0.0

Advertising