Step 4: Installing the Trim Kit

Position the two vertical trim brackets using the template as shown on Figure 3.

Mark the center line of the cutout using the template.

The template is used to locate the positions of the left and right trim brackets with
respect to the cut out. The trims are secured with three (3) screws each and the
template is discarded thereafter.

Step 3: Electrical Installation

The Thermador microwave oven is equipped with a grounded cord. The wall receptacle must
be installed and grounded in accordance with the national electrical code. Also, electrical
connections and grounding must comply with all applicable local codes.

The electrical requirements for a separate circuit serving only this microwave oven are: 120V,
60Hz, 20Amps