3–screens and menus – Tascam HD-R1 User Manual

Page 18

Advertising
background image

18

TASCAM HD-R1

3–Screens and Menus

select the next character to the right. Press the

SKIP

µ key to select the next character to the left and

clear the previous character. When finished setting the

password, press the

SKIP

key to select

SAVE

.

Press the

ENTER

key to confirm the password setting

and return to the Network Submenu.
Press the

CANCEL

key to cancel the password setting

and return to the Network Submenu and retain the

previous password.

IP Address

T

he

IP Address

set up is displayed.

IP Mode

DHCP

or

Static

. When set to

DHCP

, the

IP

Address

,

IP Mask

, and

Gateway

are

obtained automatically, provided that there is a DHCP

server on the LAN. When set to

Static

, they must

be set manually.

DHCP

is the default.

IP Address

When in

Static

mode, this is used to set the IP

Address. When in DHCP mode, the

IP Address

is obtained automatically, so it is simply displayed

here and cannot be modified.

IP Mask

When in

Static

mode, this is used to set the

IP Mask

. When in DHCP mode, the

IP Mask

is

obtained automatically, so it is simply displayed here

and cannot be modified.

Gateway

When in

Static

mode, this is used to set the

Gateway

. When in DHCP mode, the

Gateway

is

obtained automatically, so it is simply displayed here

and cannot be modified.

Parallel Port
This menu contains all settings relating to the parallel

port:

Parallel Mode

This option controls how tracks are triggered via the

parallel port. Options are

Off

,

Direct Play,

Binary Play,

or

Program Play

. See the

Parallel Interface section of this manual for details.

Input Polarity

Active Low

or

Active High

. Determines the

polarity of all parallel port input signals.

Busy1 Signal

If set to

Playback

, the busy signal is initiated

during playback.
If set to

Recording

, the busy signal is initiated

while recording.
If set to

Finished

, the busy signal is initiated for

100 ms when the HD-R1 has finished playing.
If set to

Ducking

, the busy signal is initiated when

the ducking feature is attenuating.
If set to

CF Door

, the busy signal is initiated when

the CF door is opened.
If set to

Media Full

, the busy signal is initiated

when the CF media has no space.

Busy1 Polarity

Normally Open

or

Normally Closed

.

Determines the state of the busy relay when it is idle.

Busy2 Signal

Same choices as

Busy1 Signal

.

Busy2 Polarity

Same choices as

Busy1 Polarity

.

Playlist Defaults Submenu
The items in the menu determine the default settings

for a new playlist entry. These settings also determine

how Direct Play and Binary Play modes will control

tracks when

Playback Mode

is set to

Single

,

All

, or

Folder

.

Trigger

Determines how the external input will control

playback for the track. The choices are

Trigger

(pressing button begins playback),

Momentary

(play only while button is held down), or

Toggle

(first button press plays, next button press stops).

Interruptible

Yes

or

No

. When

Yes

, the track’s playback will

be interrupted if another track is triggered before it

is finished. When

No

, the track will play to its end

before another track can be triggered.

Repeat Count

When triggered, the track will be repeated this many

times. The range is

Off

,

0

20

and

Infinite

.

Attenuation

Modifies the volume of this track at playback. The

range is -30 dB to 0 dB in 1 dB increments, the default

is 0 dB.

Advertising