Door reversal, Leveling – Tricity Bendix TB 42 UF User Manual

Page 14

Advertising
background image

14

Leveling

The appliance must be level. Level the appliance by

adjusting the two adjustable feet (1) at the front of the

appliance.

Door Reversal

If required the opening direction of the door can be

changed as follows:

Disconnect the appliance from the electricity

supply.
Tilt the appliance backwards, resting the top edge

of the appliance on a stool or something similar.
Unscrew the adjustable feet situated on both sides

at the front (2 pieces). Remove the lower door

hinge plate by unscrewing the 3 retaining screws.
Remove the hinge pin from the bottom of the door.
Slot the hinge pin into the hole in the hinge plate.
Take the door off.

Fit the door in place on the hinge pin.
Refit the bottom hinge plate assembly on the

opposite side, taking care that the edge of the door

is parallel with the side of the cabinet.
Slot the hinge pin into the hole in the hinge plate

and relocate the hinge assembly to the opposite

location and refit using the retaining screws.

To reverse the handle proceed as follows:

Remove screw covers (if fitted) and handle retaining

screws. Remove blanking plugs on the opposite

side.
Relocate the handle to the opposite side and refit

retaining screws (covers if fitted), and replace the

blanking plugs.

Advertising