Figure 2–2. module preparation, Quick start, Evaluation module preparations – Texas Instruments TPA0242 User Manual

Page 14

Advertising
background image

Quick Start List for Platform

2-4

Quick Start

-

Evaluation module preparations

Figure 2–2. Module Preparation

11

12

13

14

GND

ROUT+

ROUT–

SE/BTL

S1

SHUTDOWN

GND

LOUT–

LOUT+

C11

C2

C13

VDD

GND

L IN+

GND

L LINE–

L HP

VDD

GND

R HP

R LINE–

GND

R IN+

C10

+

TPA00242 EVM Board

SLOP275

U1

+

TEXAS
INSTRUMENTS

R2

R1

PCBEEP

C1

C12

C6

C5

C4

R3

S2

C7

C8

C9

C3

SHUTDOWN

R4

S3

S4

HP/LINE

Table 2–4. Typical TPA0242 EVM Jumper Settings

EVM

S3

TPA0242

OFF

Note:

ON = Shunt installed, OFF = Open

11) To allow the module SE/BTL control input to switch the amplifier IC

between single ended (SE) and bridge-tied load (BTL) output modes, set
output mode jumper S3 to

OFF. To keep the module amplifier IC in the

single-ended output mode regardless of the control input state, set jumper
S3 to

ON.

12) To allow the module HP/LINE control input to switch the amplifier IC

between using the HP pins and the LINE pins as the signal inputs, set the
input mode jumper S3 to

OFF. To keep the amplifier IC in the HP input

mode regardless of the control input state, set jumper S3 to

ON.

-

Power Up

13) To allow the amplifier IC to switch from the LINE inputs to the HP inputs

when the output switches from BTL output mode to SE output mode and
vice versa, set jumper S4 to

ON. To allow the inputs and output modes to

switch independently, set jumper S4 to

OFF.

Platform LED2 should light indicating the presence of V

DD

, and the evaluation

modules installed on the platform should begin operation.

14) Adjust the signal source level as needed.