6therma-tru, Light commercial/multi-family - hardware locations, Hardware locations – Therma-Tru Light Commercial Doors and Frames User Manual

Page 6: Standard steel entrance doors

Advertising
background image

6

Therma-Tru

®

Light Commercial/Multi-Family - Hardware Locations

NOMINAL

2-0

2-4

2-6

2-8

2-10

3-0

3-6

ACTUAL

23 11/16"

27 11/16"

29 11/16"

31 11/16"

33 11/16"

35 11/16"

41 11/16"

NOMINAL

6-8

7-0

8-0

ACTUAL

78 5/8"

82 1/8"

93"

MORTISE PREP

45 1/4"

45 1/4"

59 5/8"

CYLINDRICAL PREP

44 7/8"

44 7/8"

59 1/4"

STANDARD 1 3/4" DOOR, HINGE and CYLINDER LOCK LOCATIONS:

DOOR WIDTH

DOOR HEIGHT

JOB NUMBER

PROJECT

LOCATION

SHEET NUMBER OF

HARDWARE LOCATIONS

NOMINAL FRAME OPENING WIDTH

STRIKE

LOCA

TION

NOMINAL

FRAME

OPENING

HEIGHT

NOTE:

BASE FRAME = 16-GA.

CLOSURE FRAME = 22-GA.

9

7/8”

30”

30”

UNDERCUT OPTIONS:
STANDARD - 1 3/4"
PUBLIC ACCESS - 1 1/8"
NO SILL OPTION - 3/4"

STANDARD STEEL ENTRANCE DOORS

NOMINAL WIDTH (FRAME OPENING)

ACTUAL WIDTH

9 3/4"

6-8

7-0

9 3/4"

YOUR REP. FOR MORE INFO.

2 3/8" OR 2 3/4"
BACKSET (STD.)

5 1/2" DEADBOLT

FLOOR

SQUARE EDGE

CYLINDRICAL

LOCK

30"

30"

30"

30"

MOR

TISE

LOCK

PREP

1/8"

ACTU

AL

HEIGHT

NOMINAL

HEIGHT

(FRAME

OPENING)

1

3/4"

UNDER

CUT

ST

ANDARD

NOTES:

HINGE BACKSET = 5/32"

22 GA. = .027 MIN.

24 GA. = .023 MIN

DOORS UNDER 6-8 OR

OVER 7-0 ARE AVAILABLE.
CONTACT YOUR REP. FOR

MORE INFO.

Advertising