Sync recording with trim function, Automatic track division, 5 − recording – Teac CD-RW901 User Manual

Page 28

Advertising
background image



TASCAM CD-RW901

When audio signal is not detected for more than five
seconds, the CD-RW901 automatically will stop record-
ing and enter record standby mode.

S_LVL

REC ready

level

time

Five seconds

NOTE

When the input level drops below the adjusted
threshold level for more than five seconds, record-
ing stops automatically and enters in recording
ready mode.

3. To cancel the Sync recording mode, press the

SYNC REC

key. Recording returns to normal

and continues till you press the

STOP

key or the

source signal stops.

Pressing the

STOP

key stops recording.

The setting remains when the function is set on
again.

NOTE

If you set the value so that only high-level signals
trigger recording, remember that the start of a
piece may not be record as in the diagram.

Recordsing starts

level

time

This part of the

track may not be

recorded

S_LVL

Also remember that when recording from an ana-
log source, the threshold should be set so that it is
higher than the “noise floor”. If the “noise floor” is
higher than the threshold, a false start will occur:

S_LVL

level

time

Noise is higher

than threshold

Start of track is not registered

Sync recording with trim function

This Sync trim function allows you to override the auto-

matic sync recording where necessary, to chang the start

time of the track forwards or backwards.
Use the SYNC TRIM option in the REC sub-menu to
turn the function on (see “Operation basics” on page
16).

The available trim range is from -125 through +125

frames.
Turn the

MULTI JOG

dial to adjust the trim value.

Automatic track division

The trigger level can also be used to divide tracks if the
A_TRACK (auto track) function is enabled.

When this function is enabled, the unit automatically
inserts a track division in the recorded material.

To enable or disable automatic track division:
1. Use A_TRK option in the REC sub-menu to set

the mode on. The

A.TRACK

indicator at the top right

of the display lights.

2. Rotate and push the

MULTI JOG

dial to select

and enter the modes following:

DD (digital direct)

When recording digitally from MD, CD or DAT, this

mode detects a track boundary and divides the track.
However, when the DD mode is on, and if the analog
source or non-DAT/CD/MD digital connections are
detected, the track number will be incremented using

level detection, as set with the A_TRK LEVEL set-
ting as described here.

When AES/EBU is selected, this mode cannot be

used.

Level

When the sound level has dropped below the thresh-

old for more than two seconds, and sound has
re-started, the track will be divided.

Use A_TRK LEVEL option in the REC sub-menu.

The trigger level is set to -24dB to -72 dB.

A_LVL

At least

2 seconds

level

time

Track increment