Call Processing Devices (servers and related storage systems)

Typically, additional server and storage resources are added to handle call

processing, voice messaging and other telephony applications. Such

systems tend to reside within the data center and are multi-vendor in origin.

For configuration assistance specific to your rollout, please contact

Tripp Lite. Tripp Lite maintains interactive sizing and configuration resources

at www.tripplite.com/selector. We also welcome your contact with our

technical staff via [email protected] or (773) 869-1234.

Common Tripp Lite UPS Systems Recommended for VoIP Networking
Device Applications (Specifications & Runtime Charts)

UPS System Specifications

Input

Nominal

Voltage

Output

Capacity

Outlet

Outlet

Input Plug

Model

Range

Voltage

(VA/Watts)

Quantity

Type

Type

RU

Depth

Bypass

SmartOnline On-Line UPS Systems
SU2200RTXL2Ua

65-138

120

2200/1600

7

6 (5-20R)

5-20P

2U

19 in.

Internal

(110/120)

1 (L5-20R)

SU3000RTXL3U

65-138

120

3000/2400

9

4 (5-15R)

5-20P

3U

26 in.

Internal

(110/120)

4 (5-20R)

1 (L5-30R)

SU3000RTXL3UHV

160-275

208/240

3000/2400

8

6 (6-20R)

L6-20P

3U

21 in.

Internal

2 (L6-20R)

SU5000RT3U

156-276

208 & 120

5000/3500

16

2 (L6-20R)

L6-30P

7U

21 in.

Internal

2 (L6-30R)

12 (5-20R)

SU5000RT3UHV

156-276

208/240

5000/3500

4

2 (L6-20R)

L6-30P

5U

21 in.

Internal

2 (L6-30R)

SU5000RT4U

65-140

208/240

5000/3800

12

8 (5-15/20R)

L14-30P

4U

30.75 in.

Internal/External

(L-N)

& 120

2 (L6-20R)
2 (L6-30R)

SU6000RT3U

156-276

208/240

6000/4200

Hardwire*

Hardwire*

Hardwire*

9U

26 in.

Internal/External

& 120

SU6000RT4U

65-140

208/240

6000/4200

12

8 (5-15/20R)

L14-30P

4U

30.75 in.

Internal/External

(L-N)

& 120

2 (L6-20R)
2 (L6-30R)

SU8000RT3U

156-276

208/240

8000/6400

6

4 (L6-20R)

Hardwire

6U

31.5 in.

Internal/External

2 (L6-30R)

SU8000RT3U1TF

156-276

208 & 120

7500/6000

18

12 (5-15/20R)

Hardwire

8U

31.5 in.

Internal/External

4 (L6-20R)
2 (L6-30R)

SU8000RT4U

65-140

208/240

8000/5600

8

Hardwire

Hardwire

4U

34 in.

Internal/External

(L-N)

& 120

4 (5-15/20R)

2 (L6-20R)
2 (L6-30R)

SU10000RT3U

156-276

208/240 10000/8000

6

4

(L6-20R)

Hardwire

6U

31.5

in. Internal/External

2 (L6-30R)

SU10000RT3U2TF

156-276

208 & 120

10000/8000

30

24 (5-15/20R)

Hardwire

10U

31.5 in.

Internal/External

4 (L6-20R)
2 (L6-30R)

SU10KRT3U

156-276

208/240

10000/8000

Hardwire

Hardwire

Hardwire

9U

31.5 in.

Internal/External

& 120

SU16000RT4U

65-140

208/240

16000/11200

+13 Hardwire Hardwire

8U

40.5

in.

Internal/External

(L-N)

& 120

5 (5-15/20R)

2 (L6-30R)

6 (C19)

* SU6000RT3U can provide outlets when used with optional back panel accessory (SUPDM12) which provides two L6-20R, one L6-30R and ten 5-20R outlets and