Troubleshoot 17 – TANDBERG D4068 User Manual

Page 17

Advertising
background image

6

7

Troubleshoot

How do I enable full logging for Conferencing (TC-

SPI)?

To help troubleshoot any problems with the Conferencing (TCSPI) module,

add the following lines to the SametimeDiagnostics_Telephony.properties:

# Default global logging level.
# This specifies which kinds of events are logged across
# all loggers. For any given facility this global level
# can be overridden by a facility specific level
# Note that the ConsoleHandler also has a separate level
# setting to limit messages printed to the console.

.level=FINEST
net.tandberg.tms.integration.caius.tcspi.level=FINEST
net.tandberg.tms.integration.caius.tcspi.post.level=FINEST

This will create a verbose tcspi log (telephony_0.log), found in the Trace

directory of the <Domino> directory, typically c:\program files\lotus\domino\

Trace\telephony_0.log

To undo the logging, set the values back to INFO.

Conference control center in TMS does not reflect

my actions in Sametime Connect conferences

The TCSPI software uses the dial-in address to identify what TMS-ID each

Sametime user has in each conference. This is because there is no require-

ment to have the Sametime users imported into TMS for using the Movi for

IBM Lotus Sametime software.

If TMS does not update the actions in Sametime connect, verify that the SIP

proxy defined for the clients are the same as the one defined for TCSPI.

Open caius.properties (e.g. C:\Program Files\Lotus\Domino\data\domino\

html\caius.properties)

Value SIPProxy=

Open conferenceManager.properties (e.g. C:\Program Files\Lotus\

Domino\conferenceManager.properties)

Value SIPProxyServer=

Verify that these values are the same

How do I turn on logging from the Movi for IBM

Lotus Sametime plugin?

To setup logging on each clients, perform the following steps

Open sametime.properties file, in the Sametime directory, typically c:\

Program Files\ibm\Sametime Connect\sametime.properties
Update the following properties in the file to these values

.level=FINEST
logger.level=FINEST

Restart your Sametime connect client
Open C:\Documents and Settings\<username>\Application Data\

1.

2.

3.

1.

2.


3.
4.

Advertising