Frequency response measurements

Multiburst Flag Amplitude:

Measured from the center point

of the flag top to the ensuing

bottom of the flag. Result

expressed as % of sampled bar

amplitude. See element C1 and

CCIR Recommendation 567.

Multiburst Amplitude (five

packets): Measured as the

peak-to-peak amplitude of each

of the first five multiburst

packets. The peak-to-peak

amplitude is measured over a

4.5 µsec window at the center

of the first two packets, and

over a 1.13 µsec window at the

center of the next three packets.

The last packet is not measured.

Results expressed as % of

sampled flag amplitude. See

elements C1 and C2 and CCIR

Recommendation 567.

Linear waveform distortion

measurements

Baseline Distortion: Measured

as the difference between the

signal level 400 nanoseconds

after the half-amplitude point

of the trailing edge of the bar,

and the signal level at blanking

reference. The signal is first

band-limited to 3.3 MHz. Result

expressed as a % of sampled

bar amplitude. Sign is positive

if level nearest bar is highest.

See CCIR Recommendation 569

(paragraph 2.4) and Figure 1.

2T Pulse/Bar Ratio Error: Meas-

ured as the difference between

the sampled amplitude of the

2T pulse and the sampled bar

amplitude. The sign is positive

if the 2T pulse amplitude is

greater. Result expressed as a

% of sampled bar amplitude.

See elements B1 and B2 and

CCIR Recommendation 569.

Low frequency error

Low Frequency Error: Measured

as the peak-to-peak amplitude

of the most extreme sampled

fluctuations from black-level

that are in the frequency band

between 10 Hz and 2 kHz.

Expressed as a % of sampled bar.

When ordering, please use the nomenclature given here. The standard instrument is shipped as a rack mount product.

Included Accessories

Instruction manual; 75

Ω terminators (3) 011-0102-00; power cord.

Options

Option 01 — NTSC Measurements

Option 01/11 — Dual Standard Measurements

Option 20 — Teletext Measurements

Option 21 — Camera Measurements

Option 30 — Component Measurements

Option 40 — Audio Measurement Module

Option 41 — 6 Channel Audio Measurement Module

Option 42 — Audio to Video Delay Measurement

Option 48 — GPIB Interface

Option 1C — Cabinet Version

Option 1G — Echo/Rounding Measurements

Option 1P — Printer

Option 1Z — Probe Adapter (067-1429-00)

Option 3Z — Probe Adapter (3 each of 067-1429-00)

VM700T Software Utilities

VMBKUP — VM700T Backup Utility

VMREMGR — Remote Graphics Software for the VM700T

VMT — VM700T Remote Control Software

Optional Accessories

VM7FC1 — Field installable conversion kit to convert rackmount unit to cabinet.

VM7FR1 — Field installable conversion kit to convert cabinet to rackmount unit.

Ordering
Information

VM700T

Option 11

PAL Video

Measurement Set.

Elements C1 and C2 (CCIR Recommendation 569).