Thank  you  for  purchasing  a  Taylor®  infrared  thermometer.  Please  read  this  instruction  manual  carefully  before  use. 
Keep these instructions handy for future reference. 

The thermometer is a non­contact infrared thermometer. Simply aim the thermometer at the target and press the ‘Scan 
key’ to display the surface temperature.

Temperature Reading Operation
Press the ‘Scan key’ to take a temperature
reading. The unit will display the
temperature of the target for 10 seconds
then turn off automatically.

CAUTION!

1. WHEN DEVICE IS IN USE, DO NOT

LOOK DIRECTLY INTO THE LASER
BEAM–PERMANENT EYE DAMAGE
MAY RESULT.

2. USE EXTREME CAUTION WHEN

OPERATING THE LASER.

3. NEVER POINT THE DEVICE TOWARDS

ANYONE’S EYES.

4. KEEP OUT OF REACH OF ALL CHILDREN.

Continuous Temperature Reading Operation 

1. Press and hold down the “Scan” key. 
2. The unit will display continually updated real time temperature readings while the “Scan” key is held down. When the 
key is released, the last temperature will display for 10 seconds, and then the unit will turn off automatically.

HACCP CHECK 

The  “HACCP  CHECK”  feature  is  incorporated  in  our  thermometer 
temperature to graphically indicate critical temperature zone. The icons and 
LED  indicators  located  above  the  display  indicate  if  a  food  product is  in a 
safe or unsafe HACCP “Danger Zone” temperature. The green and red LED 
light will always be lit before the power is turned off. 
A  Green  LED  light  with  a  ” 

”  icon  indicates  a  safe  cool  or  frozen 

condition  below  40 

F  (4 

C),  while  a  ” 

”  icon  indicates  a  safe  holding 

temperature above 140 

F (60 

C). 

When  the  temperature  is  between  40 

F  (4 

C)  and  140 

F  (60 

C),  the  red 

LED with a” 

” icon will appear and indicate that the temperature is fallen within the HACCP “Danger Zone” from 40 

to 140 

F (4~60 

C)

.

°C OR °F MODE 

To change the thermometer from ‘°C’ to ‘°F’ or from ‘°F’ to ‘°C’, first turn the instrument on by pressing the ‘Scan key’, 
then press the ‘Mode key’ one time. The ‘°C’ or ‘°F’ symbol will flash. Press the ‘Scan key’ to change to scale.

EMISSIVITY RANGE 

The  infrared  thermometer  is  supplied  with  a  default  emissivity  of  0.95.  The  emissivity  of  the  thermometer  can  be 
changed  from  0.05  (5E)  to  1  (100E).  Changes  should  only  be  carried  out  by  experienced  personnel. To  change  the 
emissivity,  firstly  turn  the  instrument  on  by  pressing  the  ‘Scan’  button,  then  press  the  ‘Mode’  button  two  times  for 
emissivity function. The 95E will flash on the LCD screen, then press the ‘Meas.’ button to adjust the emissivity value, 
press the  ‘Mode’ button  again  to exit  the set up screen. For information relating to  the emissivity  of specific materials, 
please contact the nearest retailer. Note: non­contact infrared thermometers are not recommended for use in measuring 
the temperature of shiny or polished metals.

BAR DISPLAY:

The fixed setting range for bar display is 68­428°F (20~220°C) and Center=248°F (120°C). 

The bar display will be updated comply with the measurement reading changed

.

LCD ERROR MESSAGES 

The thermometer incorporates visual diagnostic messages as follows: 

」 

‘Hi’  or  ’Lo’  is  displayed  when  the  temperature  being  measured  is  outside  of  the  range  of  the 
instrument, ‘Hi’ when higher than +662°F (+350°C) and ‘Lo’ when lower than ­67°F (–55°C). 

」 

‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature. 
‘Er3’  is  displayed  when  the  ambient temperature  of the  thermometer  EXCEEDS  32°F (0°C)  OR 
+122°F  (+50°C).  In  both  cases  you  should  allow  plenty  of  time  (minimum  30  minutes)  for  the 
thermometer to stabilize to the working/room temperature. 

」 

For all other error messages it  is  necessary  to reset the thermometer.  To reset the thermometer, 
turn  the  instrument  off,  remove  the  battery  and  wait  for  a  minimum  of  one  minute,  reinsert  the 
battery  and  turn  on.  If  the  error  message  remains,  please  contact  Customer  Service  for  further 
assistance.

BATTERIES 

The thermometer incorporates visual low battery indication as follows: 

‘Battery OK’: 

measurements 

are possible 

‘Battery Low’: battery needs to 

be replaced, measurements 

are possible 

‘Battery Exhausted’: 

measurements are 

not possible