TOA Electronics CST-38 User Manual

Page 19

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

19

If there is a continuous perpendicular side wall
closer than 18" (mm) from the CST-38 fireplace
opening, it must be protected with a 40 x 40" x
¹⁄₂" (1016 mmx 1016 mm x 13 mm) wall shield
constructed of millboard or a durable noncom-
bustible material with an equal or greater insu-
lating value than k = .84 BTU IN/FT

2

HR

°

F or a

thermal resistance that equals or exceeds r =
1.19 HR

°

F FT

2

/BTU IN. A continuous side wall

can not be closer than 7" (178 mm) from the
nearest side of the CST-38 fireplace.

Secure the hearth extension to the floor to
prevent possible shifting.

A continuous perpendicular combustible side
wall can not be closer than 7" (178 mm) from
the nearest side of the CPF-38 fireplace. A wall
shield is not required.

Note: Any noncombustible material whose k
value is less than .84 or whose r value is more
than 1.19 is acceptable.

Hearth Extension Dimensions

CST-38

CPF-38

A

16"

16"

(406 mm)

(406 mm)

B

28

¹⁄₂"

32

¹⁄₂"

(724 mm)

(826 mm)

C

8"

8"

(203 mm)

(203 mm)

D

44

¹⁄₂"

48

¹⁄₂"

(1130 mm)

(1232 mm)

Figure 56

A

B

D

C

C

Figure 57

Figure 58

B

A

C

C

8" (203 mm) Min.

to Fireplace Opening

Side Wall

Model CST-38

D

B

A

C

C

25

³⁄₁₆"

Optional

End Opening

Hearth

Extension

8" (203 mm) Min.

to Fireplace Opening

Side Wall

Model CPF-38

Using the r formula:

Desired

r value of listed

Min. thickness

Required = material (per inch)x of Listed
Thickness r value of desired

Material

material (per inch)

T

M

(inches) = 1.19 x T

L

r

M

T

M

(inches) = 1.19

x

1"

2.33*

Answer using r = 0.51 x

1" = .051 = ¹⁄₂"

¹⁄₂" thickness Micore will be required.

Methods of Determining Hearth Extension
and Wall Shield Equivalents

To determine the thickness required for any
material when either the k or r values are
known:

T

M

= Thickness of material in inches

k

M

= K value of desired material

r

M

= R value of desired material

T

L

= Minimum listed thickness

Example: Micore CV230 is to be used for the
hearth extension fireplace. How thick must this
material be?

Using the k formula:

Desired

k value of desired

Min. thickness

Required = material (per inch) x of Listed
Thickness k value of listed

Material

material (per inch)

T

M

(inches) =

k

M

x T

L

.84

T

M

(inches) = 0.43* x

1"

0.84

Answer using k = 0.51 x

1" = 0.51 = ¹⁄₂"

¹⁄₂" thickness Micore will be required.

At times it is important to know what combina-
tion of materials are acceptable for use as
hearth extensions. The “R values” are used to
determine acceptable combinations of materi-
als because “R values” are additive where r and
k values are not.

Alternative Hearth Extension

and Wall Shield Materials

Listed

Values

Min. Thick

Material

k

r

T

L

Millboard

.84

1.19

1"

Alternative

Values

Min. Thick

Materials

k

r

T

M

Wonderboard

1.92

0.56

2

¹⁄₄"

Common brick

5.00

0.20

6"

Cement mortar

5.00

0.20

6"

Ceramic tile

12.5

0.08

14

⁷⁄₈"

Marble

11.0

0.09

13

¹⁄₈"

Micore CV230

0.43

2.33

¹⁄₂"

(U.S. Gypsum)

Ceraform 126

0.27

3.70

³⁄₈"

(Johns-Manville)

Advertising