Installation – Thomas & Betts 15D User Manual

Page 27

Advertising
background image

Part No. 90-0123-00
Libertycombi.p65 10/26/98

27

• Remove the positive (+) battery cable

terminal cover from the unit and attach the
battery cable. Tighten the battery terminal bolts
to a torque value between 160 inch-pounds
and 180 inch-pounds. Replace the cover for
the positive terminal.

The negative (-) cable should be

connected directly to the negative post of the
house or auxiliary battery bank or the ground
side of a current shunt. Tighten securely.

The positive (+) battery cable must be

fused and connected to the positive post of the
house or auxiliary battery bank, or through a
selector switch to one or more battery banks.

A spark may be generated when the final

battery connection is made. This is normal; do
not be alarmed. However, do not make the final
connection in the presence of flammable
fumes.

If multiple batteries are used, the

interconnecting jumper cables must be the
same AWG or larger as those connected to
the inverter/charger.

NOTE: If installing in a vehicle, do not use the
vehicle frame as the negative conductor.

If multiple battery banks are to be

charged, a battery bank selector switch can be
installed, allowing the banks to be charged
either individually or simultaneously. A solenoid
can also be used. The PathMaker Battery
Combiner, by Heart Interface, may be used to
connect multiple battery banks. The
PathMaker battery combiner is available from
your Heart dealer.

INSTALLATION

POSITIVE (+)

(Battery Cable

Cover on)

PathMaker Models

70 Amp, 2 Channel

100 Amp, 2 Channel
100 Amp, 3 Channel
200 Amp, 2 Channel
200 Amp, 3 Channel

PathMaker 100, 2 Channel

NEGATIVE (-)

(Battery Cable

Cover on)

Freedom 15D

Advertising
This manual is related to the following products:

20D, 15, 20