8

Mounting or exchanging a pick-up cartridge


Instead of the factory-supplied pick-up cartridge
any
other cartridge with standard half-inch mounting
holes and a weight between 3 and 10 grams can be
installed.
Unscrew the cartridge and carefully remove the
coloured signal leads from the cartridge pins with a
pair of tweezers. Screw the new cartridge onto the
head shell but do not tighten. Attach the leads to the
pins while observing the correct coding:


R

=

red

right channel

RG

=

green

right channel ground

L

=

white

left channel

LG

=

blue

left channel ground

Fig. 8

Electrical Safety


This device is in conformity with international safety regulations (IEC 65) and
EC regulations76/499/EWG.

ATTENTION!

During these mounting and adjustment procedures you must be very careful not to dam-
age the delicate stylus and cantilever by uncontrolled and brisk movements.