Trango Broadband High Density Mesh System User Manual

Page 7

Advertising
background image

HD Mesh Node

Trango Broadband Wireless — High Density MESH

page 7

Section 2 Getting Started

It is always a good idea to first provision and test the equipment on the bench before deploying them in the
field. This is a particularly useful exercise for the novice user.

Opening the Box


Open the box by flipping up the quick release lockable latches.








Connections and Power

Figure 3

• Power is applied to the HD Mesh unit via the Power Input Terminals located at the bottom left hand

corner inside the box.

• There are 5 PoE ports to provide connection to 5 Trango Broadband radios. Connect a Cat-5 (straight

through) Ethernet cable (Trango Broadband recommends shielded twisted pair) between the POE
port of the HD Mesh unit and the RJ-45 connector on the radio.

• Both green LEDs on the POE of the HD Mesh should be lighted, indicating power is present to the

POE as well as the radio. (Figure 3)

Flip Up

Pull away from box

Quick
Release
Lockable
Latch

Note: Improper wiring of
power may power unit but
may cause damage to
system.