8-1.

FAULT IN EXCHANGE

Before power supply check, confirm the following three

points to eliminate elementary faults:

1. Is

voltage

selector set correctly?

2. Is

AC

power

supplied?

3. Is

power

switch O N ?

Start checking after disconnecting all wiring connected
to DC output of the power supply unit.

SYMPTON

CHECK-ITEM

Over-current flows into one
of plug-in units.

Fault in the power supply
unit DS-510.

Exchange does not

operate.

All DC output
voltages are

correct.

All or one of

DC output
voltages are
not correct.

Abnormal voltage

of +24V terminal.

Right range:
+24 ~ +30V

Replace AC and DC fuses.

Incorrect setting of the

voltage selector.
Faulty power transformer.

DC/DC inverter (MIV-02) is

defective.

Replace PCB of charging

circuitry.

Abnormal voltage

of +18V.

Abnormal voltage

of +5V or +12V.

Battery is not

charged.

Right range:

Right range:

Check the cur-
rent flowing
into the bat-
tery.

Right range:

AC & DC operation

lamps are OFF.

Buzzer does not
operate.

Note: Only when DC

power supply

(Battery) is

employed.

Blown AC and/or
DC fuse.

Check all DC

voltage.

Replace PCB of charging

circuitry.

All DC output

voltages are

correct.

heck all sta-

tions involv-
ed in All-Call

paging.

Over-current flows into one
of plug-in units.

(Especially on +18V)

MIV-02 is defective.

Replace

fuse

according

to

the following.

Number of stations

0

~

30

31

~

64

65

~

Fuse

DC 5A
DC 7A
DC 10A

-62-