Atm cable specifications – Transition Networks MEDIA CONVERTER A-CF-01 User Manual

Page 2

Advertising
background image

straight-through

crossover

<100 meters

Fileserver

<100 meters

25 Mb/s or 155 Mb/s ATM Switch

2 kilometers - multimode
20 kilometers - singlemode

Straight Through/Crossover Cable Requirements and Pin Specifications

The two active pairs in an
ATM network are pins 1 & 2
and pins 7 & 8. Use only
dedicated wire pairs (such as
blue/white & white/blue,
orange/white & white/orange)
for the active pins.

1. Is the power LED on the media converter illuminated?

NO

Is the power adapter the proper type of voltage and cycle frequency for your AC outlet?
NOTE: Refer to the “Power Supply Requirements” on the back page.

Is the power adapter properly installed in the media converter and in the outlet?

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 2.

2. Is the TX Activity LED illuminated?

NO

Check UTP cables for proper connection and pin assignment. (See above.)

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 3.

3. Is the Fiber Activity LED illuminated?

NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to RX and TX ports,
respectively, on the other 100BASE-FX device.

Refer to Tech Tips available at: http://www.transition.com

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

KEEP TWISTED-PAIR RUNS AS SHORT AS POSSIBLE.

Connect the power supply cable to the media converter BEFORE connecting to the outlet.

Install unit with PSU provided. (Output 9 VDC regulated, 500 mA).

Troubleshooting the Media Converter

Installation Notes

If the ATM media converter fails, determine the answers to the following questions:

Twisted
Pair #1

Twisted
Pair #2

Crossover Cable

Connectors for like devices

1

2

7

8

1

2

7

8

1

2

7

8

Twisted
Pair #1

Twisted
Pair #2

Straight Through Cable

Connectors for unlike devices

1

2

7

8

Be certain that the twisted-pair cable is configured
correctly (straight through or crossover) for site
. Cable
connections between an ATM switch and the media converter must
be configured as straight through. Cable connections between the
media converter and a NIC must be configured as crossover.

The physical characteristics of the media cable must meet or exceed the
specifications: ATM UNI 3.1 #AF-PHY-0015
Maximum number of media converters in series:

2

ATM CABLE SPECIFICATIONS

FIBER CABLE SPECIFICATIONS

SINGLEMODE
Fiber Optic Cable Recommended:

9 µm singlemode fiber

Fiber Optic Transmitter Power:

min: -15.0

dBm

max: -8.0

dBm

Fiber Optic Receiver Sensitivity:

min: -31.0

dBm

max: -8.0

dBm

Wavelength:

1300nM

Bit error rate:

10

-9

Maximum Cable Distance:

20 kilometers

MULTIMODE
Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

min: -19.0

dBm

max: -14.0

dBm

Fiber Optic Receiver Sensitivity:

min: -30.0

dBm

max: -14.0

dBm

Wavelength:

1300nM

Bit error rate:

10

-9

M i

C bl Di

2 kil

COPPER CABLE SPECIFICATIONS

Category 5 wire or better is required. Either shielded twisted-pair (STP) or
unshielded twisted-pair (UTP) can be used. DO NOT USE FLAT OR SILVER
SATIN WIRE.

Category 5:

Gauge

24 to 22 AWG

Attenuation

20 dB/1000’ @ 10 MHz

Impedance 100

±10% @ 10 MHz

Maximum Cable Distance:

100 meters (330 feet)