Chapter 3: Replacing Pre-Installed Components

M1205 HDD Start-Mode & ID Selection Switch

SW1 & SW2 HDD Start-Mode Selection Switch

Case

SW1
(DLYD_START)

SW2
(RMT_START)

Motor Spin Func-
tion

1

OFF

OFF

Motor spins up at
D.C. power on.

2*

ON

OFF

Motor spins up at
D.C. power on after
a delay in seconds
12 times** the value
of the numeric
SEL_ID for the SCSI
device.

3

OFF

ON

Motor spins up only
when START UNIT
command is
received.

4

ON

ON

Reserved. SCSI
devices not imple-
menting this option
shall execute power
control according to
the rules of case 3.

Note:
*Case 2 is the default setting.
**This value may be reduced by SCSI device supplies to reflect the
wrost-case time duration of peak current drains at the 12 V.D.C or 5
V.D.C source or both during motor spin up. In no case should the
delay exceed 12 s.