Using the generator, Operation, System ground – Troy-Bilt 030245 User Manual

Page 8: Connecting to a building’s electrical system, Generator location, Warning

Advertising
background image

8

USING THE GENERATOR

System Ground

The generator has a system ground that connects the
generator frame components to the ground terminals on
the AC output receptacles.The system ground is connected
to the AC neutral wire (the neutral is bonded to the
generator frame).

Special Requirements

There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction.

• In some areas, generators are required to be registered

with local utility companies.

• The generator's receptacles and the provided adapter

cord set are not protected by a Ground Fault Circuit
Interrupter (GFCI). If used on an OSHA governed job
site, appropriate GFCI protection must be utilized.

Connecting to a Building’s Electrical

System

Connections for standby power to a building’s electrical
system must be made by a qualified electrician.The connection
must isolate the generator power from utility power, and must
comply with all applicable laws and electrical codes.

Generator Location

Generator Clearance

Place generator in a well ventilated area, which will allow
for removal of deadly exhaust gas. DO NOT place
generator where exhaust gas could accumulate and enter
inside or be drawn into a potentially occupied building.
Ensure exhaust gas is kept away from any windows, doors,
ventilation intakes or other openings that can allow exhaust
gas to collect in a confined area (Figure 3). Prevailing winds
and air currents should be taken into consideration when
positioning generator.

• When using generator for backup power, notify utility

company. Use approved transfer equipment to isolate
generator from electric utility.

• Use a ground fault circuit interrupter (GFCI) in any damp or

highly conductive area, such as metal decking or steel work.

• DO NOT touch bare wires or receptacles.
• DO NOT use generator with electrical cords which are worn,

frayed, bare or otherwise damaged.

• DO NOT operate generator in the rain or wet weather.
• DO NOT handle generator or electrical cords while standing

in water, while barefoot, or while hands or feet are wet.

• DO NOT allow unqualified persons or children to operate or

service generator.

Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.

WARNING

4

Section

Operation

• Keep at least 5 ft. (152 cm) clearance on all sides of generator

including overhead.

Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.

WARNING

Figure 3 — Generator Clearance

Exhaust Port

Typical Generator Shown

Using a generator indoors WILL KILL YOU
IN MINUTES.

Exhaust contains carbon monoxide, a
poison gas you cannot see or smell.

NEVER use in the home

or in partly enclosed

areas such as garages.

ONLY use outdoors and

far from open windows,

doors, and vents.