Advertising
background image

4

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Figure 5

CAUTION: DO NOT ATTEMPT TO TOUCH THE
DOORS WITH YOUR HANDS WHILE THE FIRE-
PLACE IS IN USE. ALWAYS USE DOOR
HANDLES. DOORS WILL BECOME VERY HOT
WHEN FIREPLACE IS IN USE.

WARNING: FIREPLACES EQUIPPED
WITH OPTIONAL ACCESSORY DOORS
SHOULD BE OPERATED ONLY WITH
THE DOORS FULLY OPEN OR FULLY
CLOSED (

FIGURE 4 ). THIS APPLI-

ANCE MAY ONLY BE FITTED WITH
DOORS CERTIFIED FOR USE WITH
THE APPLIANCE.

Figure 4

AVERTISSEMENT: POUR UTILISATION
UNIQUEMENT AVEC LES PORTES EN
VERRE CERTIFIÊES AVEC L'APPAREIL.

Figure 3

COMBUSTION AIR CONTROLS

Many appliances are equipped when installed
with an outside combustion air vent system
that is designed to provide the appliance with
outside make-up air for combustion when in
operation.

WARNING: DO NOT USE ABRASIVE
CLEANERS. NEVER CLEAN THE GLASS
WHEN IT IS HOT.

4. Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before re-light-
ing, refer to the lighting instructions in this
manual. Instructions are also found on a pull-
out panel located on the floor of the appliance.

5. Always keep the appliance area clear and free
from combustible materials, gasoline and other
flammable liquids.

6. Remember, Millivolt appliances have a con-
tinuous burning pilot flame. Exercise caution
when using products with combustible vapors.

7. Clean the optional glass doors only when
necessary. Wipe surface with clean, damp-
ened, soft cloth. Follow with dry, soft towel as
desired. Take care not to scratch the glass
surface.

Honeywell Electronic

Gas Valve

Combustion
Air Actuator

ON/OFF Switch

Electronic
Gas Control
Valve

Inlet
Pressure
Port

Manifold Pressure Port

OFF

IN

PSI

ON

CONTROL

IG
N

IT
E

R

Fully Open or

Fully Closed

Spark Ignitor

SIT Millivolt Valve

Gas Control Knob

O

N

OF

F

P

I L

OT

Gas Control Knob

Spark Ignitor

Honeywell Millivolt Valve

IN

OUT

TPTH

TP

TH

PI

LOT

PI

L

O

T

ON

it

OFF

Figure 2

If the appliance is not equipped with a wall
switch or remote control, the main burner must
be turned off and on with the gas control
switch. Toggle the switch from ON to OFF to
operate the main burner from ON to OFF.

2. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This is
due to the “burn-in” of internal paints and
lubricants used in the manufacturing process.

3. Keep lower control compartment clean by
vacuuming or brushing at least twice a year.
More frequent cleaning may be required due to
excessive lint from carpeting, bedding materi-
als, etc. It is important that control compart-
ments, burners and circulating air passage-
ways of the appliance be kept clean.

The actuator for combustion air system is
standard on all appliances but must not be
operated if the complete system is not in-
stalled. Refer to

Figures 5 and 6. When the

complete outside combustion air vent system
is installed, the installer will remove the actua-
tor locking screw.