Caution – Thermos 465621303 User Manual

Page 16

Advertising
background image

16 • Grill2Go

Leak Testing (20 lb. Refillable)

IMPORTANT!

For your safety



Use mild soap and water.

Do not use household cleaning agents.

(A)

Leak test must be repeated each time LP tank is exchanged or refilled.
Do not smoke during leak test.
Do not use an open flame to check for gas leaks.
Grill must be leak checked outdoors in well-ventilated area, away from ignition sources
such as gas fired or electrical appliances. During leak test, keep grill away from open flames
or sparks.

Use a clean paint brush and 50/50 soap and water solution.

Damage to gas train components can result.

Brush soapy solution onto the shaded areas shown below

.

s

A

If “growing” bubbles appear do not use or move
the LP tank. Contact an LP gas supplier or your
fire department.

CAUTION

Connecting The Adapter Hose

To The LP Tank

full stop

(sold separately)

1. Use only adapter hose approved by safety testing

organizations (CSA, UL, etc).

2. Turn all control knobs to the OFF position.
3. Turn LP tank OFF by turning hand-wheel

clockwise to a

.

4. Remove the protective cap from LP tank valve.

Always use cap and strap supplied with valve.

(This section continued on next page.)

Use of this POL transport plug
(plastic part with external threads)
will defeat safety feature of valve.

Off Clockwise

OPD Hand
Wheel

Type 1 outlet
with thread
on outside.

Safety relief valve

Strap and cap

Advertising
This manual is related to the following products: