13.3 Biamp System Parameters



Parameter

Unit/Name

Low Section

High Section


Gain

(dB) 0

-1.0

Delay

(ms) 0.167 0

Polarity

Positive

Positive


HPF Ä

Freq (Hz)

42.5

1680

Slope (dB/oct)

24

24

Filter Shape

Butterworth

Linkwitz Riley

LPF

Freq (Hz)

1470

Thru

Slope (dB/oct)

24

NA

Filter Shape

Linkwitz Riley

NA


Freq (Hz)

62.5

2720

Level (dB)

+7

-4

Type Parametric

Parametric

PEQ 1 Ä

Q / Bandwidth 2.0 / 0.5000

2.1 / 0.4719

Freq (Hz)

454

10700

Level (dB)

-3

+5

Type Parametric

Parametric

PEQ 2

Q / Bandwidth 1.7 / 0.5946

1.9 / 0.5297

Freq (Hz)

642

15100

Level (dB)

-2

+3

Type

Parametric

2.4 / 0.4204

PEQ 3

Q / Bandwidth 4.0 / 0.2500

NA

Freq (Hz)

1010

NA

Level (dB)

+6

NA

Type Parametric

NA

PEQ 4

Q / Bandwidth 4.0 / 0.2500

NA

Freq (Hz)

NA

NA

Level (dB)

NA

NA

Type NA

NA

PEQ 5

Q / Bandwidth NA

NA



Ä

Note : When using the V12HP with subs, set HPF on LF section @ 80 – 110Hz

(24dB/oct LR) and omit PEQ1 (on LF only)

PEQ 1 (on LF only) may also be omitted when using the V12HP as a floor monitor.