Factory Default Setting

3-2

3.1

Factory Default Setting

The EVM board is set to its default configuration from factory as described on
the table below to operate in bipolar

±

10V mode of operation using the internal

reference.

Table 3-1. Factory Default Jumper Setting

Reference

Jumper

Position

Function

W1

OPEN

VREF output pin is floated and not used for offset adjustment.

W2

2-3

REFEN pin is tied to AGND to enable 10 V internal reference.

W3

1-2

REFOUT pin is strapped to REFIN to provide 10 V internal voltage reference.

W4

OPEN

Onboard external reference through U3 is disconnected.

W5

1-2

Negative supply rail of U2 op-amp is supplied with -15 V.

W6

OPEN

REFADJ pin is floated.

W7

CLOSE

RFB2 pin is strapped to VOUT pin for DAC output feedback.

W8

CLOSE

TEST pin is tied to DGND.

W9

OPEN

SJ pin is floated.

W10

OPEN

RFB1 is floated.

W11

CLOSE

AGND and DGND are tied together to a common point.

W12

1-2

Positive supply rail of U2 op-amp is supplied with 15 V.

W13

3-4

Buffered output of DAC is channeled through to J5 and J4-2.

W14

OPEN

External reference is disconnected from the negative input of U2 to configure U2 for
unity gain.

W15

OPEN

Configure U2 op-amp for unity gain.

W16

OPEN

RSTSEL pin is tied high to set DAC reset value to midscale.

W17

OPEN

RST pin is tied high by default.