Tyco KT-400 Expansion Module KT-MOD-OUT16 User Manual

Kt-mod-out16

Advertising
background image

Tel.: 1 (450) 444 2030

Toll Free: 1-888-222-1560 Fax: 1 (450) 444 2029 Internet: www.kantech.com

DN1781-0809

Copyright © 2008 Tyco International Ltd. and its Respective Companies. All Rights Reserved.

• Specifications may change without notice.

Kantech and the Kantech logo are trademarks of Tyco International Ltd. and its Respective Companies.

KT-MOD-OUT16

KT-400 Expansion Module 16-Output with SPI Cable Install Sheet

1. Introduction

The KT-MOD-OUT16 is a 16 zones output module. It can be

used for elevator access control (may require additional

hardware).
The module supports daisy chaining; you can interconnect up to

16 KT-MOD-OUT16 modules for a total of 256 external outputs

per KT-400. You can mix relays and outputs in the same SPI

group, up to 256 outputs.
Note 1: The KT-400 SPI port maximum current draw, when the

12V AUX terminals are not used, is 500 mA.
Note 2: External power supply (12 VDC, 2 Amps) is required

when the total current draw exceeds 500mA on the SPI Port.
Note 3: There are already 4 relays available on the KT-400.

Make sure to check the relays number assignments to prevent

redundancy unless it has been planned on purpose.

2. Specifications

Maximum Current draw: up to 750 mA per module

Connects to the KT-400 via the 6-pin SPI connector

16 outputs low current module, 5 to 24 VDC, 4 to 750 mA

Can be used for elevator access control or general output

Can be mixed with output module KT-MOD-REL8 in the
same SPI group

3.

Installing the KT-MOD-OUT16

3.1. Unpacking

The KT-MOD-OUT16 package includes the following parts:

One (1) KT-MOD-OUT16 module, 14 cm x 8 cm (5.7 in x
3.25 in)

One (1) SPI cable with 1 SPI connector, 41 cm (16 in)

Four (4) plastic standoffs

Two (2) installation sheets, English and French

3.2. Mounting

The KT-MOD-OUT16 can be installed inside a compatible cabinet

(KT-MOD-CAB or KT-400) or mounted in a dry and secure

location at less than 1 m (3 ft) from the KT-400.

Perform the following steps to mount the unit:
1. Press the four (4) plastic standoffs through the mounting

holes of the cabinet,

2. Secure the cabinet to the wall in the desired location. Use

appropriate wall anchors when securing the cabinet to

drywall, plaster, concrete, brick or other surfaces,

3. Press the module into the plastic standoffs to secure the

module to the cabinet.

Once the unit is mounted, wiring may be started.

3.3. Installation and Wiring

Before beginning to wire the unit, ensure that all power (AC

transformer and battery) is disconnected from the KT-400.
Perform the following steps to complete wiring:
1. Connect the 6-pin SPI connector to:

the KT-400 SPI port, or

the SPI OUT of the previous output module (KT-MOD-

REL8 and KT-MOD-OUT16 only), or

the SPI EXP of the 1st input module KT-MOD-INP16

connected to the KT-400 SPI port.

2. Connect the six SPI wires (blue (BLU), white (WHT), green

(GRN), yellow (YEL), black (BLK) and red (RED)) to the SPI

IN (TB1) terminals.

3. Connect the 6-pin SPI connector from the SPI OUT to the

next output module (KT-MOD-REL8 and KT-MOD-OUT16

only).

4. Complete all output wiring.