Performance, Engineering data - hrv rnc20 dimensions hrv, Thermally conductive, patented aluminum core – Tradewins Furniture RNC20 User Manual

Page 4: Motors and blowers, Filters, Mounting the hrv, Defrost, Case, Weight, Shipping weight

Advertising
background image

4

0107

THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE

The cross-flow heat recovery core transfers heat between the two air streams.
It is easily removed for cleaning or service.

MOTORS AND BLOWERS

Each air stream has one centrifugal blower driven by a common PSC motor.

FILTERS

Washable air filters in exhaust and supply air streams.

MOUNTING THE HRV

Four threaded inserts at corners of case designed to accept four PVC reinforced
polyester straps that are supplied with the unit.

DEFROST

Damper defrost system; defrosts automatically as the outdoor temperature falls.

CASE

Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to
prevent exterior condensation. Drain connections two - 1/2" (12mm) OD.

WEIGHT

63 lbs. (28.7 kg)

SHIPPING WEIGHT

67 lbs. (30.4 kg)

CONTROLS - HRV System Control

HRV defaults to LOW SPEED when plugged in. HIGH SPEED option is accessible by connecting
remote controls to designated terminals inside electrical box of HRV.

Standard LOW SPEED SETTING can be increased to medium low.
Off (Standby)/Low or OFF/HIGH speed operation is also available.

OPTIONAL ACCESSORIES

99-101

Crank Timer

99-116

Dehumidistat Ventilation Control - Dehumidistat with ON/OFF

99-130

Dehumidistat Control - Dehumidistat

99-132

20 Minute Fan Timer - (3 wire) 20 gauge wire (min.) 100’ length (max.)

99-186

Weatherhoods, Two - 6" (150mm) c/w 1/4" (6mm) mesh screen

99-2040 20/40 ON/OFF Dehumidistat

All units conform to CSA and UL standards.

WARRANTY

Units carry a 15 year warranty on the heat recovery core and a five year replacement
parts warranty.

33-5/8"

STALE AIR

TO OUTSIDE

FRESH AIR

FROM OUTSIDE

STALE AIR

FROM INSIDE

FRESH AIR

TO INSIDE

CONDENSATE DRAINS

BLOWERS

DEFROST

DAMPER

DEFROST

PORT

*

All Duct Connections 6"(150mm)

FILTERS

*NOTE:
Front clearance of
25 inches (635 mm)
is recommended
for ser vicing unit.

19"

(483)

14 3/4"

(375)

BALANCING DAMPER

Engineering Data - HRV

RNC20

Dimensions HRV

inches (mm)

TM

HEAT RECOVERY VENTILATOR

HEAT RECOVERY VENTILATOR

Date: ___________________________________________

Tag: _____________________Qty:___________________

Project: _________________________________________

Engineer: _______________________________________

Contractor: ______________________________________

Supplier: ________________________________________

Quote#: _________________________________________

Submitted by: ____________________________________

*Sensible Efficiency - thermal **Latent Efficiency - moisture

Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency - takes into account all power inputs

Performance

(HVI certified)

Net supply air flow in cfm (L/s) against external static pressure

E.S.P

(external static pressure)

[cfm (L/s)]

@ 0.1" (25 Pa)

214 (101)

@ 0.2" (50 Pa)

206 (97)

@ 0.3" (75 Pa)

193 (91)

@ 0.4" (100 Pa)

184 (87)

@ 0.5" (125 Pa)

170 (80)

@ 0.6" (150 Pa)

155 (73)

@ 0.7" (175 Pa)

137 (65)

Max. Temperature Recovery

69%

Sensible Effectiveness
@ 119 cfm (56 L/s)

32°F (0°C)

67%

*Sensible Efficiency
@ 119 cfm (56 L/s)

32°F (0°C)

60%

*Sensible Efficiency
@ 117 cfm (55 L/s)

-13°F (-25°C)

60%

VAC @ 60HZ

120

WATTS / Low speed.

70

WATTS / High speed

182

Amp rating

1.4

1

2

3

20

40

60

80

100

120

140

160

180

200

220

240

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

Static Pressure (in w.g.)

A

ir

Flow (

c

fm

)

3 - High Speed
*2 - Medium Low Speed
*1 - Low speed

*Manufacturer’s data

Advertising