TROUBLESHOOTING

14

121

p/n
4532

4

Op

M

anual Counter

top
Ga

s G

riddle

s

DESCRIPTION

POSSIBLE PROBLEM

SUGGESTED REMEDY

Pilot will not light

Gas supply off

Check main / unit gas valves

Air in lines

Turn gas valve on. Attempt to light
pilot every 15 sec.

Pilot valve not on or not depressed

Refer to page 10 for pilot lighting
instructions

Burners won’t light

Pilot light not lit

Turn off gas — allow unit to
vent for 5 minutes. Turn gas back on
and light pilot

Control not on

Turn temperature control to desired
temperature

Individual burner won’t

light

Water in burner

Remove burner and dry
thoroughly

Damaged temperature control,
burner or other internal component

Contact Authorized Wells
Service Agency for repairs

Burner not hot enough

Temperature control not set

Adjust for desired temperature

Shutter or nozzle out of adjustment

Contact qualified technician for
adjustment

Damaged temperature control,
element or other internal component

Contact Authorized Wells
Service Agency for repairs

Grease drawer full or not installed

Empty grease drawer.
Install properly

Damaged internal component

Contact Wells Authorized Service
Agency for repairs

NOTE: There are no user serviceable components in the griddle. In all
cases of damage or malfunction, contact your Authorized Wells Service
Agency for repairs.