United States Stove Company DR6 User Manual

Page 6

Advertising
background image

6

CAC

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

CHIMNEY LENGTH
FLUSH WITH INSIDE
OF FLUE

NONSOLUBLE
REFACTORY
CEMENT

MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211

CHIMNEY CONNECTOR
TO HEATER

MINIMUM CLEARANCE
9 IN. ALL AROUND

SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)

CHIMNEY FLUE

SOLID INSULATED, LISTED
FACTORY-BUILT CHIMNEY LENGTH

USE CHIMNEY MFRS. PARTS TO
ATTACH CONNECTOR SECURELY

AIR SPACE

PART B
FIGURE 5 -
(FIGURE 5 CONTINUED)

AIR SPACE
9 IN. MINIMUM

FACTORY-BUILT
CHIMNEY LENGTH

CHIMNEY FLUE

MINIMUM CHIMNEY CLEARANCE TO
BRICK AND COMBUSTIBLES IS 2 IN.

MINIMUM CLEARANCES 12
IN. OF BRICK ALL AROUND

CHIMNEY CONNECTOR TO
HEATER

FIRE CLAY LINER
(5/8" MIN. WALL THICKNESS)

MIN. 3-1/2" THICK BRICK
MASONRY WALL

MASONRY CHIMNEY
CONSTRUCTED TO
NFPA 211

MINIMUM 12 IN.
TO COMBUSTIBLES

PART A, FIGURE 7
(FIGURE 7 CONTINUED ON NEXT PAGE)

There are basically two methods of metal prefabricated chimney installation. One method is to install the chimney inside
the residence through the ceiling and the roof. The other method is to install an exterior chimney that runs up the outside
of the residence.
REMEMBER: Follow the chimney manufacturer's installation instructions and maintain the manufacturer's specified clear-
ance distance.
Additional chimney informationis presented throughout this manual. READ IT THOROUGHLY TO BE MORE THOR-
OUGHLY INFORMED.

CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY THROUGH A COMBUSTIBLE WALL