13 washing the atomiser, 1 circuit washer and tank washer, Washing the atomiser – Unigreen Super Spalliera User Manual

Page 16: Circuit washer and tank washer, Ab c f p

Advertising
background image

16 unigreen

4.13 WASHING THE ATOMISER
After every treatment, thoroughly clean the equipment, washing it with water
inside and out. Dirty equipment is very dangerous for people and in particular
for children.
Discharging the residues of washing in the environment without taking
precautions is forbidden as this pollutes water courses. Distribute the
residues on the field or the crops where they won’t cause any damage.
WARNING: the indications to follow for using chemical products are indicated
in paragraph 2.2.1.

4.13.1CIRCUIT WASHER AND TANK WASHER
Some machine models are fitted with a circuit washer tank (FIG.17). This
tank must be filled with clean water and used to rinse the entire circuit
including the suction, delivery, pump, pressure regulator, jets and nozzles.
Thanks to the practical rotary nozzle it also rinses the inside surfaces of the
tank.
NB: To completely clean the tank and the pipes of any residues of the various
active principles, we recommend adding 2kg of soda to the washing liquid for
every 100 L of water.

At the end of the treatment, wash the circuit and the tank.

a)

Stop the diaphragm pump disengaging the power-takeoff.

b)

Check you have filled the circuit washer tank (C).

c)

Make sure the main control of the pressure regulator is OFF and that all

the boom sectors are closed.
d)

Turn suction deviator A to the circuit washer position (H2O).

e)

Start the diaphragm pump by engaging the power-takeoff.

f)

Increase the engine speed until all of the liquid in circuit washer tank C

has been sucked up.
g)

Turn the diaphragm pump off and turn deviator A to the work position

(TANK).
h)

Turn the main control to ON, so there is pressure in the circuit.

i)

Start the diaphragm pump again and use the tank washing tap on the

regulator (or on pump P) that supplies jet B.
j)

After a few minutes you can close the tank washing tap

k)

Distribute the washing residues over a portion of the field where it won’t

cause damage.
l)

After you have finished washing, stop the diaphragm pump.

NB: at the end of the washing cycle, if there is the risk of frost, pour roughly
500 grams of normal antifreeze for auto vehicles into the tank.

FIG. 16

A

B

C

F

P

This symbol identifies
the clean water tank
on the machine used
to wash the circuit

WARNING: using the taps on the pump or in any
case on the front of the machine puts the operator
near the cardan shaft. Despite the presence of
protections at CE rule, it is compulsory to switch
off the engine and to take the key off.

Advertising
This manual is related to the following products: