SPECIFICATIONS

Natural Gas
Manifold Pressure Setting 4" w.c.
Gas Inlet Pressure

Maximum 10-1/2" w.c.
Minimum 5" w.c.

Gas Rate

Number

Model Number

Type

Max BTU/Hr

Min BTU/Hr

of Burners

9830N

Manual

30,000

8,000

2

Propane / LPG

Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.

Manifold Pressure Setting 10" w.c.
Gas Inlet Pressure

Maximum 13" w.c.
Minimum 11" w.c.

Gas Rate

Number

Model Number

Type

Max BTU/Hr

Min BTU/Hr

of Burners

9830L

Manual

30,000

8,000

2

Controls - Main control has 4 positions:

1. OFF - All gas to the gas logs is shut off at the control
2. IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries
3. PILOT - Valve position to light / maintain a standing pilot
4. ON - Gas flow to complete system, front burner ignition

Front Burner Control Knob - Infinite control, rotate clockwise to minimum rate and counter

clockwise for maximum rate.

Rear Burner Control Knob - Has 3 positions:

1. OFF - Gas to rear burner is shutoff at control
2. ON/MAX - Maximum gas flow to rear burner
3. MIN - Minimum gas flow rate to rear burner

5

GLOVES ARE RECOMMENDED WHEN HANDLING CERAMIC FIBER LOGS
TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS. LOGS ARE
FRAGILE, HANDLE WITH CARE.

Carefully inspect the contents for shipping damage and immediately inform your dealer if any damage is found.

CAUTION

9830L and 9830N Unvented Gas Heaters

1. Packet containing Homeowners/Installation instructions.
2. Log box containing four (4) fiber ceramic logs, refer to installation instructions.
3. Unvented gas heater.

CHECK THAT ALL LISTED PARTS HAVE BEEN RECEIVED