PART E - (Figure 5)
In addition to the methods shown by A, B, C, and D of Figure 5, a listed factory-built wall pass-through system may
be purchased and installed according to the instructions packaged with it to provide a safe method of passing
chimney connector through a combustible wall for a connection to a masonry chimney.

If the chimney connector does not have to pass through a combustible wall to get to a masonry chimney, simply connect
the chimney connector directly to the masonry chimney's chimney thimble as described and shown by parts C and D of
Figure 5. Remember, the chimney connector should extend into the chimney thimble to the innerface of the chimney flue
but not beyond; if the chimnney connector is extended through the chimney thimble into the chimney flue, resistance to the
flow of smoke and gases up the chimney will occur; that flow resistance will have an adverse affect on the operation and
performance of the heater and venting system.

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

CHIMNEY LENGHT
FLUSH WITH INSIDE
OF FLUE

NONSOLUBLE
REFACTORY
CEMENT

MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211

CHIMNEY CONNECTOR
TO HEATER

MINIMUM CLEARANCE
9 IN. ALL AROUND

SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)

CHIMNEY FLUE

SOLID INSULATED, LISTED
FACTORY-BUILT CHIMNEY LENGHT

USE CHIMNEY MFRS. PARTS TO
ATTACH CONNECTOR SECURELY

AIR SPACE

PART B
FIGURE 5 -
(FIGURE 5 CONTIN-
UED)

AIR SPACE
9 IN. MINIMUM

FACTORY-BUILT
CHIMNEY LENGHT

SHEET STEEL SUPPORTS

CHIMNEY SECTION

CHIMNEY
CONNECTOR

AIR SPACE
2 IN.

TWO VENTILATED AIR
CHANNELS EACH 1 INCH.
CONSTRUCED OF
SHEET STEEL.

PART C
FIGURE 5

PART D
FIGURE 5

MINIMUM CLEARANCE
2 IN. ALL AROUND

CHIMNEY THIMBLE

1 IN. AIR SPACE TO
CHIMNEY LENGHT

MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211

SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)

CHIMNEY CONNECTOR
TO HEATER

CHIMNEY FLUE

SOLID INSULATED, LISTED
FACTORY-BUILT CHIMNEY
LENGHT (12 IN. LONG MIN.)

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211

SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)

CHIMNEY CONNECTOR
TO HEATER

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

MINIMUM 6 IN. GLASS
FIBER INSULATION ALL AROUND

24 GAUGE
VENTILATED THIMBLE WITH
TWO 1 INCH AIR CHANNELS

CHIMNEY THIMBLE

CHIMNEY FLUE

CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY WHEN CHINEY CONNECTOR

DOES NOT PASS THROUGH A COMBUSTIBLE WALL