User’s manual – U-Line CLR2060 User Manual

Page 28

Advertising
background image

26

User’s Manual

2.

Remove the screws securing the front access panel (see Figure
29).

Figure 30 – Ice Thickness Adjustment Dial

3.

Locate the ice cube thickness adjustment dial on the control board
(see Figure 30). Turn the dial clockwise (+ number) to thicken or
counterclockwise (- number) to thin the ice bridge.

Ice thickness adjustment dial can be adjusted 1/4 to 1/2
of a turn on the number dial. Allow the ice maker to stabi-
lize for 24 hours before making further adjustments. Since
ice cubes in any given batch will vary, choose cubes from
the sample area for comparison when making adjustments
(see Figure 31). The factory setting is 0.

ICE004A

DIAL IS FACTORY

SET TO 0

ICE CUBE THICKNESS

ADJUSTMENT

DIAL

0

1

2

3

4

5

-5

-4

-3

-1

Body_UM.qxd 12/17/04 9:16 AM Page 26

Advertising