Door reversal – U-Line CO2175RF User Manual

Page 15

Advertising
background image

CO2175FF, 2175RF

15

Door Reversal

Figure 19

Black and white units may be left- or right-hand opening.
Stainless steel unit doors cannot be reversed. The doors
are easily reversed by moving the hinge hardware to the
opposite side. The top hinge hardware will be used on the
bottom of the other side and the bottom hinge hardware
will be used on the top of the other side (Figure 19).

To reverse the door:

Figure 20

1. Remove top hinge screw pin (Figure 20, 1) from door

using a Phillips screwdriver. Remove door by tilting
forward and lifting off bottom hinge pin.

Figure 21

2. Remove plastic screw plugs (three each, top and

bottom) (Figure 21, 1) from new hinge location. Do
not discard.

3. Remove top hinge (three screws) (Figure 20, 2) and

reinstall hinge screw pin (Figure 20, 1).

Figure 22

4. Install the removed top hinge mount on opposite side

BOTTOM (Figure 22).

Figure 23

ULIN_0015_A

1

2

ULIN_0003_A

1

ULIN_0002_A

1

ULIN_0005_A

1

ULIN_0004_A

Advertising