11 filling the tank, 12 mixing, 1 manual premixing – Unigreen CAMPO 11 - 16 - 22 - 32 User Manual

Page 16: 2 premixer on cover (optional), Spraying computer (optional), Filling the tank, Mixing

Advertising
background image

16 unigreen

4.11 FILLING THE TANK

The machines for defensive crop treatments, in consideration of the safety
of persons, animals and the protection of the environment, must only be
filled indirectly from open water courses and only by free-falling water from
the waterworks.
The pipe used for filling must never come into contact with the liquid
inside the tank and therefore the water must always fall over the upper
edge of the filling inlet and through the filter installed on it.
The tank is fitted with a transparent graduated band that shows the exact
quantity of liquid inside. This reading is precise if the tank is on flat ground;
the actual total capacity coincides with the highest number. All the filling
systems fitted by Unigreen on their production machines or on request are
antipollution and stop the liquid overflowing out of the tank.

a)FILLING WITH THE 3-WAY DEVIATOR (Fig. 7).
It is possible to fill the tank using the pump and the floating filter kit G

(cod.1002/0080F) with 6 metres of rubber hose (the floating filter lets you
always and only suck up clean water).
= connect hose T to deviator D using the union hose adaptor supplied.
= turn the lever of deviator D to the filling position.
= place the other end of the hose, on which you fitted filter G, in the watering
point.
= start the power-takeoff leaving pressure regulator C in the draining position
(you don’t have to put the pump under pressure).
= the filling speed in litres/minute is equal to the delivery of pump P.
= visually check the level of the liquid in the tank and after filling stop the
pump and put the lever of deviator D back in the working position.
= disconnect pipe T from deviator D.

4.12 MIXING
The active principle can be mixed using the relevant stirrers before and during
the treatment. Correct mixing and stirring is the basis of the correct distribution
on the crops. We recommend some useful accessories such as the premixer
for powders and liquids (see the following paragraph).

To mix the product in the tank proceed as follows:

a) high-pressure machines from 30 to 60 bar (FIG. N° 8a): run the stirrer (RED
tap) or the ejector (GREEN tap) for roughly 10-15 minutes at the maximum
pressure available

b) low pressure machines, max 20 bar
= with a drilled pipe on the drain, run the pump at roughly 540 RPM with the
pressure regulator on drain for at least 10-15 minutes. (FIG. N° 8b)
= with the stirrer on a delivery, run the pump supplying the stirrer (or ejector) at
the maximum pressure available for at least 10-15 minutes. (FIG. N° 7)

4.12.1

MANUAL PREMIXING

Dilute the active principle by hand before introducing it into the tank, (you must
wear suitable protective clothing such as rubber gloves, a mask or goggles,
overalls, etc.).

4.12.2

PREMIXER ON COVER (OPTIONAL):

Open the cover and pour all of the chemical powder into the filter, close the
cover and open the supply tap until all of the powder has dissolved.

3-way deviator for filling tank

Level indicator and
graduated band

FIG. 8a

FIG. 8b

FIG. 7

WARNING: using the taps on the pump or in any

case on the front of the machine puts the operator

near the cardan shaft. Despite the presence of

protections at CE rule, it is compulsory to switch off

the engine and to take the key off.

Advertising
This manual is related to the following products: